ELE14-00952
| Final | 5/19/2014 | 5/19/2014 | 5/19/2014 3:38:41 PM | P | FAIL |
|
|
rosalie Phone #: ###-#### Home owner has not called for conference as reqwested on form PDS 424-B. I requested a conference to discuss issues with service and some dangerous over head conductors to out building. Overhead conductors are at 6'9", 7'3" and 8" to out building. shall be removed due to hieght and illegal terminations. Wires shall be properly terminated exiting house. BCC 4-05-32 Code violation not to be retained. Owner's son not available to meet so sent a friend so I could inform of issues. 110.26 work platform needs 36" depth from front of service.
|
ELE14-01163
| Electrical Rough-In | 5/19/2014 | 5/19/2014 | 5/19/2014 2:52:33 PM | P | PASS |
|
|
Greg Critchfield is contact ###-####, service wiring. thank you Phone #: ###-#### >> Inspection requested via web by Debby Pierce Conduits for new elevator equiptment rough in ok
|
ELE12-00802
| Final | 5/19/2014 | 5/19/2014 | 5/19/2014 2:27:29 PM | P | PASS |
|
|
Greg Critchfield is contact, ###-####. thank you Phone #: ###-#### >> Inspection requested via web by Debby Pierce This permit covers installation of new service and prep work to provide conduits and junction points for quick disconnect of old gear and quick reconnect to new. Future permit will cover the change over from old gear to new gear. Conference in 2012 electrician stated city gave permission to feed fire pump from normal and emergency power in rigid conduit with out fire barrier. For work done to this point Final ok
|
ELE14-00791
| Electrical Rough-In | 5/19/2014 | 5/19/2014 | 5/19/2014 12:59:54 PM | P | PASS |
|
|
This is a grid inspection. Contact on the job is Nate Cornell. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery 1 st floor corridor, 2nd floor 2 offices, library, engeneering grid rough in ok cover
|
ELE14-01134
| Final | 5/16/2014 | 5/19/2014 | 5/19/2014 9:58:25 AM | A | PASS |
|
|
Troy Phone #: ###-#### Final ok
|
ELE14-00158
| Electrical Rough-In | 5/16/2014 | 5/19/2014 | 5/19/2014 9:11:47 AM | A | CANC |
|
|
Service Inspection, not sure if i clicked the right "Inspection Type". Geoff Hannaford is the contact on this project, ###-####. thank you. Phone #: ###-#### >> Inspection requested via web by Debby Pierce Needed P/S inspection
|
ELE14-00158
| Permanent Service | 5/19/2014 | 5/19/2014 | 5/19/2014 9:11:31 AM | P | PASS |
|
|
Service Inspection, not sure if i clicked the right "Inspection Type". Geoff Hannaford is the contact on this project, ###-####. thank you. Phone #: ###-#### >> Inspection requested via web by Debby Pierce p/s o/h n ok
|