ELE13-02817
| Final | 5/19/2014 | 5/19/2014 | 5/19/2014 3:42:05 PM | P | PASS |
|
|
HP. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy final ok
|
ELE14-00875
| Final | 5/19/2014 | 5/19/2014 | 5/19/2014 2:45:44 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI NEC 314.21 Drywall repairs in master bathroom not completed nor anybody on site working on correction. Clearance problem on working space of service meter resolved.
|
ELE14-01278
| Final | 5/19/2014 | 5/19/2014 | 5/19/2014 2:00:49 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov job complete, final ok
|
ELE14-01278
| Electrical Rough-In | 5/19/2014 | 5/19/2014 | 5/19/2014 1:52:14 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov rough-in ok
|
ELE14-01162
| Final | 5/19/2014 | 5/19/2014 | 5/19/2014 1:32:50 PM | P | PASS |
|
|
job complete, final ok
|
ELE14-01162
| Electrical Rough-In | 5/19/2014 | 5/19/2014 | 5/19/2014 1:32:30 PM | P | PASS |
|
|
Jonathon-please call 45 minutes prior Phone #: ###-#### correction done, rough-in ok cover
|
ELE14-01141
| Final | 5/19/2014 | 5/19/2014 | 5/19/2014 1:06:29 PM | P | PASS |
|
|
Went to location thinking we needed to cable for and add a camera. when on site all we needed to do was plug patch cable into DVR. Phone #: ###-#### >> Inspection requested via web by Matt Phillips final ok
|
ELE12-00817
| ELE-Aging Inspection | 5/19/2014 | 5/19/2014 | 5/19/2014 10:19:18 AM | | DONE |
|
|
see final
|
ELE12-00817
| Final | 5/19/2014 | 5/19/2014 | 5/19/2014 10:18:47 AM | P | PASS |
|
|
job complete, final ok
|
ELE13-02314
| Final | 5/19/2014 | 5/19/2014 | 5/19/2014 9:31:39 AM | P | PASS |
|
|
Jay Phone #: ###-#### job complete, final ok
|
ELE14-01227
| Temporary Service | 5/17/2014 | 5/19/2014 | 5/19/2014 9:20:17 AM | A | PASS |
|
|
Please contact Tracy ###-#### with any questions. Phone #: ###-#### >> Inspection requested via web by Tracy Robertson t/s u/g n ok
|
ELE14-01162
| Final | 5/16/2014 | 5/19/2014 | 5/19/2014 9:17:44 AM | A | FAIL |
|
|
Jonothan or H.O. Evon ###-#### Phone #: ###-#### NEC 250.32(A) Separate grounded and a grounding conductor are required for service to detached structure NEC 300.4(D) Shall not staple NM cable within 1 1/4 of edge of framing member
|
ELE14-01162
| Electrical Rough-In | 5/19/2014 | 5/19/2014 | 5/19/2014 9:05:07 AM | A | PASS |
|
|
Jonothan or H.O. Evon ###-#### Phone #: ###-#### Rough-in ok cover trench
|