Inspections for the day of: Monday, May 19, 2014.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02817 Final5/19/20145/19/20145/19/2014 3:42:05 PMPPASS
HP. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy final ok
ELE14-00875 Final5/19/20145/19/20145/19/2014 2:45:44 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI NEC 314.21 Drywall repairs in master bathroom not completed nor anybody on site working on correction. Clearance problem on working space of service meter resolved.
ELE14-01278 Final5/19/20145/19/20145/19/2014 2:00:49 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov job complete, final ok
ELE14-01278 Electrical Rough-In5/19/20145/19/20145/19/2014 1:52:14 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov rough-in ok
ELE14-01162 Final5/19/20145/19/20145/19/2014 1:32:50 PMPPASS
job complete, final ok
ELE14-01162 Electrical Rough-In5/19/20145/19/20145/19/2014 1:32:30 PMPPASS
Jonathon-please call 45 minutes prior Phone #: ###-#### correction done, rough-in ok cover
ELE14-01141 Final5/19/20145/19/20145/19/2014 1:06:29 PMPPASS
Went to location thinking we needed to cable for and add a camera. when on site all we needed to do was plug patch cable into DVR. Phone #: ###-#### >> Inspection requested via web by Matt Phillips final ok
ELE12-00817 ELE-Aging Inspection5/19/20145/19/20145/19/2014 10:19:18 AM DONE
see final
ELE12-00817 Final5/19/20145/19/20145/19/2014 10:18:47 AMPPASS
job complete, final ok
ELE13-02314 Final5/19/20145/19/20145/19/2014 9:31:39 AMPPASS
Jay Phone #: ###-#### job complete, final ok
ELE14-01227 Temporary Service5/17/20145/19/20145/19/2014 9:20:17 AMAPASS
Please contact Tracy ###-#### with any questions. Phone #: ###-#### >> Inspection requested via web by Tracy Robertson t/s u/g n ok
ELE14-01162 Final5/16/20145/19/20145/19/2014 9:17:44 AMAFAIL
Jonothan or H.O. Evon ###-#### Phone #: ###-#### NEC 250.32(A) Separate grounded and a grounding conductor are required for service to detached structure NEC 300.4(D) Shall not staple NM cable within 1 1/4 of edge of framing member
ELE14-01162 Electrical Rough-In5/19/20145/19/20145/19/2014 9:05:07 AMAPASS
Jonothan or H.O. Evon ###-#### Phone #: ###-#### Rough-in ok cover trench