Inspections for the day of: Tuesday, May 19, 2015.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00091 ELE-Aging Inspection5/19/20155/19/20155/20/2015 12:31:05 PM DONE
Still under construction
ELE12-02903 ELE-Aging Inspection5/19/20155/19/20155/20/2015 12:30:19 PM DONE
Still under construction
ELE13-00104 ELE-Aging Inspection5/19/20155/19/20155/20/2015 12:29:57 PM DONE
Waiting on return phone call from contractor
ELE12-02275 ELE-Aging Inspection5/19/20155/19/20155/20/2015 12:14:34 PM DONE
Still under construction
ELE15-01465 Final5/19/20155/19/20155/19/2015 3:28:04 PMPCANC
Phone #: ###-#### Inspection requested via web by Dustin Kuester needed temp service inspection
ELE15-01465 Temporary Service5/19/20155/19/20155/19/2015 3:20:59 PMPFAIL
Phone #: ###-#### Inspection requested via web by Dustin Kuester 110.7 installations shall be free of short circuits. Ground wire touching terminal in meterbase
ELE15-00565 Final5/19/20155/19/20155/19/2015 2:45:12 PMPFAIL
Phone #: ###-#### Inspection requested via web by ron spen cer as per 314.25 all boxes shall have covers 408.4 service disconnecting means shall be clearly indentified 422.52 drinking fountains shall have GFCI protection.
OK to install cubicals
ELE15-01190 Permanent Service5/19/20155/19/20155/19/2015 1:53:02 PMPPASS
This is a billboard structure located on the north side of Franklin RD just West of Cloverdale. Meter was removed with anticipation of removing billboard sign. Plans changed and the sign will stay in place. We extended the weather-head away from the catwalk and installed new service wire. Phone #: ###-#### Inspection requested via web by David Mackey p/s o/h rec ok
ELE15-01190 Final5/19/20155/19/20155/19/2015 1:52:09 PMPFAIL
This is a billboard structure located on the north side of Franklin RD just West of Cloverdale. Meter was removed with anticipation of removing billboard sign. Plans changed and the sign will stay in place. We extended the weather-head away from the catwalk and installed new service wire. Phone #: ###-#### Inspection requested via web by David Mackey as per 408.41 grounded conductor in a panelboard shall have individual terminal that is not also used for another conductor
ELE15-01430 Electrical Rough-In5/19/20155/19/20155/19/2015 1:15:44 PMPFAIL
Phone #: ###-#### Inspection requested via web by daniel bibikov 300.4 NM cable ran through bored hole that does not maitain 1 1/4 in shall be protected from physical damage by nail plates 334.30 NM cable shall be secured with 12in of boxes A/C stub NM cables shall not be stapled on edge
ELE15-01320 Electrical Rough-In5/18/20155/19/20155/19/2015 11:13:00 AMAPASS
###-####- Steve- please call 45 min before upstairs rough-in ok cover
ELE15-00517 Final5/18/20155/19/20155/19/2015 10:32:10 AMAPASS
Phone #: ###-#### Inspection requested via web by Spencer McLean
No card posted Final ok
ELE15-00517 Electrical Rough-In5/19/20155/19/20155/19/2015 10:29:31 AMPPASS
Phone #: ###-#### Inspection requested via web by Spencer McLean grid rough in ok cover
ELE15-01328 Electrical Rough-In5/18/20155/19/20155/19/2015 10:10:02 AMAPASS
Angela Phone #: ###-#### Master bath rough-in ok to cover
ELE15-01198 Rough-In Permanent Service5/19/20155/19/20155/19/2015 9:51:46 AMAPASS
Cody is the onsite contact at ###-#### Phone #: ###-#### Inspection requested via web by Tracy Robertson Rough
-in ok to cover p/s u/g n ok
ELE15-01451 Electrical Rough-In5/18/20155/19/20155/19/2015 9:35:56 AMPCANC
Underground inspection. Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot Inspection cancelled from web by: Barbara Szurgot
ELE15-00814 Final5/18/20155/19/20155/19/2015 9:04:35 AMAFAIL
Garage code 0500. Thank you Phone #: ###-#### Inspection requested via web by daniel bibikov 110.3 receptacles shall wire as listed. reverse polarity in up north bed. 406.9 receptacle in wet location shall be flush with face plate. 410.16(b) closet luminare shall have totally enclosed lamps