Inspections for the day of: Thursday, May 19, 2016.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Little
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM16-00280 Final5/19/20165/19/20165/19/2016 3:00:46 PMPPASS
ACCESS CODE 6776
ANY QUESTIONS CALL NIKKI ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
>talked to Nikki about a couple sink leaks
PLM16-01363 Final5/19/20165/19/20165/19/2016 2:12:24 PMPPART
Juan Phone #: ###-####
>Need paper work on grease incp. which most likely needs a flow control installed.
>Temp occ ok
PLM16-00473 Final5/19/20165/19/20165/19/2016 1:18:09 PMPPASS
Juan Phone #: ###-####
PLM16-01813 Final5/18/20165/19/20165/19/2016 11:39:39 AMAPASS
Bath Planet will be on site. Phone #: ###-#### Inspection requested via web by Scott Sparrell
>ri / trim sh to sh ok
PLM16-01811 Sprinkler (Final)5/18/20165/19/20165/19/2016 11:13:27 AMAPASS
Final inspection ready for Thursday, May 19th a.m.
Thank you - Debbie Phone #: ###-#### Inspection requested via web by debbie long
PLM16-01135 Final5/18/20165/19/20165/19/2016 11:00:11 AMAFAIL
Phone #: ###-#### Inspection requested via web by Scott Hurren
>413.1 ISPC Hot water delivered from public use lavatories shall be limited to a maximum temperature of 120 degrees F by a device that conforms to ASSE 1070.
>caulk mop sink
>glue a perm cab on old drain sticking out of wall.
PLM16-01814 Water and/or Sewer5/18/20165/19/20165/19/2016 10:44:56 AMAFAIL
Phone #: ###-#### Inspection requested via web by Vaughn Carlson

>608.5 ISPC—Relief valve drain piping shall not be smaller than the relief valve outlet, material used shall not reduce the internal bore of the pipe. Flex connector is not an approved material for T&P piping.
>drill hole at 90 since T&P runs up hill.
>drain from pan is backgraded and would allow water to sit in pan. make flat.
PLM16-00752 Final5/18/20165/19/20165/19/2016 10:33:26 AMAPASS
Phone #: ###-#### Inspection requested via web by Sam Kirk
PLM16-00799 Plumbing Rough-in5/19/20165/19/20165/19/2016 9:57:18 AMAFAIL
Inspection requested via web by Brian Johansen
>does not meet cross sectional area for venting.
PLM16-01822 DOC - Permit Finaled5/19/20165/19/20165/19/2016 9:24:30 AMPPASS
PLM16-01822 Water and/or Sewer5/18/20165/19/20165/19/2016 9:24:21 AMAPASS
Phone #: ###-#### Inspection requested via web by Brett Simmons
PLM16-01821 DOC - Permit Finaled5/19/20165/19/20165/19/2016 9:23:19 AMPPASS
PLM16-01821 Water and/or Sewer5/18/20165/19/20165/19/2016 9:23:09 AMAPASS
Phone #: ###-#### Inspection requested via web by Brett Simmons
PLM16-01820 DOC - Permit Finaled5/19/20165/19/20165/19/2016 9:22:48 AMPPASS
PLM16-01820 Water and/or Sewer5/18/20165/19/20165/19/2016 9:22:33 AMAPASS
Phone #: ###-#### Inspection requested via web by Brett Simmons
PLM16-01674 Plumbing Rough-in5/18/20165/19/20165/19/2016 9:22:08 AMAPASS
Phone #: ###-#### Inspection requested via web by Branden Steers
PLM15-00618 PLM-Aging Inspection5/19/20165/19/20165/19/2016 8:01:56 AM PART
wip
PLM15-02490 PLM-Aging Inspection5/19/20165/19/20165/19/2016 8:01:17 AM FAIL
never rescheduled by contractor
PLM15-01026 PLM-Aging Inspection5/19/20165/19/20165/19/2016 8:00:17 AM FAIL
contractor seems to ignore these
PLM15-02065 PLM-Aging Inspection5/19/20165/19/20165/19/2016 7:56:34 AM PART
wip
PLM16-01812 Final5/18/20165/19/20165/18/2016 4:07:13 PMPCANC
READY AFTER 3:00PM
If you have any questions please don''t hesitate to call and ask for Laurie.
Thank You,
Holly Grago Phone #: ###-#### >> Inspection requested via web by Stacia Haumann Inspection cancelled from web by: Stacia Haumann