PLM16-00280
| Final | 5/19/2016 | 5/19/2016 | 5/19/2016 3:00:46 PM | P | PASS |
|
|
ACCESS CODE 6776 ANY QUESTIONS CALL NIKKI ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann >talked to Nikki about a couple sink leaks
|
PLM16-01363
| Final | 5/19/2016 | 5/19/2016 | 5/19/2016 2:12:24 PM | P | PART |
|
|
Juan Phone #: ###-#### >Need paper work on grease incp. which most likely needs a flow control installed. >Temp occ ok
|
PLM16-00473
| Final | 5/19/2016 | 5/19/2016 | 5/19/2016 1:18:09 PM | P | PASS |
|
|
Juan Phone #: ###-####
|
PLM16-01813
| Final | 5/18/2016 | 5/19/2016 | 5/19/2016 11:39:39 AM | A | PASS |
|
|
Bath Planet will be on site. Phone #: ###-#### Inspection requested via web by Scott Sparrell >ri / trim sh to sh ok
|
PLM16-01811
| Sprinkler (Final) | 5/18/2016 | 5/19/2016 | 5/19/2016 11:13:27 AM | A | PASS |
|
|
Final inspection ready for Thursday, May 19th a.m. Thank you - Debbie Phone #: ###-#### Inspection requested via web by debbie long
|
PLM16-01135
| Final | 5/18/2016 | 5/19/2016 | 5/19/2016 11:00:11 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Scott Hurren >413.1 ISPC Hot water delivered from public use lavatories shall be limited to a maximum temperature of 120 degrees F by a device that conforms to ASSE 1070. >caulk mop sink >glue a perm cab on old drain sticking out of wall.
|
PLM16-01814
| Water and/or Sewer | 5/18/2016 | 5/19/2016 | 5/19/2016 10:44:56 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Vaughn Carlson
>608.5 ISPC—Relief valve drain piping shall not be smaller than the relief valve outlet, material used shall not reduce the internal bore of the pipe. Flex connector is not an approved material for T&P piping. >drill hole at 90 since T&P runs up hill. >drain from pan is backgraded and would allow water to sit in pan. make flat.
|
PLM16-00752
| Final | 5/18/2016 | 5/19/2016 | 5/19/2016 10:33:26 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Sam Kirk
|
PLM16-00799
| Plumbing Rough-in | 5/19/2016 | 5/19/2016 | 5/19/2016 9:57:18 AM | A | FAIL |
|
|
Inspection requested via web by Brian Johansen >does not meet cross sectional area for venting.
|
PLM16-01822
| DOC - Permit Finaled | 5/19/2016 | 5/19/2016 | 5/19/2016 9:24:30 AM | P | PASS |
|
|
|
PLM16-01822
| Water and/or Sewer | 5/18/2016 | 5/19/2016 | 5/19/2016 9:24:21 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM16-01821
| DOC - Permit Finaled | 5/19/2016 | 5/19/2016 | 5/19/2016 9:23:19 AM | P | PASS |
|
|
|
PLM16-01821
| Water and/or Sewer | 5/18/2016 | 5/19/2016 | 5/19/2016 9:23:09 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM16-01820
| DOC - Permit Finaled | 5/19/2016 | 5/19/2016 | 5/19/2016 9:22:48 AM | P | PASS |
|
|
|
PLM16-01820
| Water and/or Sewer | 5/18/2016 | 5/19/2016 | 5/19/2016 9:22:33 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM16-01674
| Plumbing Rough-in | 5/18/2016 | 5/19/2016 | 5/19/2016 9:22:08 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Branden Steers
|
PLM15-00618
| PLM-Aging Inspection | 5/19/2016 | 5/19/2016 | 5/19/2016 8:01:56 AM | | PART |
|
|
wip
|
PLM15-02490
| PLM-Aging Inspection | 5/19/2016 | 5/19/2016 | 5/19/2016 8:01:17 AM | | FAIL |
|
|
never rescheduled by contractor
|
PLM15-01026
| PLM-Aging Inspection | 5/19/2016 | 5/19/2016 | 5/19/2016 8:00:17 AM | | FAIL |
|
|
contractor seems to ignore these
|
PLM15-02065
| PLM-Aging Inspection | 5/19/2016 | 5/19/2016 | 5/19/2016 7:56:34 AM | | PART |
|
|
wip
|
PLM16-01812
| Final | 5/18/2016 | 5/19/2016 | 5/18/2016 4:07:13 PM | P | CANC |
|
|
READY AFTER 3:00PM If you have any questions please don''t hesitate to call and ask for Laurie. Thank You, Holly Grago Phone #: ###-#### >> Inspection requested via web by Stacia Haumann Inspection cancelled from web by: Stacia Haumann
|