ELE16-00557
| Electrical Rough-In | 5/18/2016 | 5/19/2016 | 5/19/2016 3:09:09 PM | P | PASS |
|
|
Contact is Ben MacDonagh Phone #: ###-#### Inspection requested via web by Scott Campbell rough-in ok cover consultation room walls
|
ELE16-01553
| Electrical Rough-In | 5/18/2016 | 5/19/2016 | 5/19/2016 11:25:16 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jim Williams exterior corrections not completed, interior ceiling and walls ok to cover
|
ELE16-00798
| Final | 5/18/2016 | 5/19/2016 | 5/19/2016 10:40:19 AM | A | PASS |
|
|
5050 + enter Phone #: ###-#### Inspection requested via web by HZ ZAHIC final ok
|
ELE16-01327
| Final | 5/18/2016 | 5/19/2016 | 5/19/2016 10:21:40 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Tyler Bowen NEC 600.6 Disconnect for LED lettering requires to be within sight or breaker lock-out. NEC 210.8(B)(1) Bathroom receptacles requires GFCI protection NEC 422.52 Electric drinking fountain requires GFCI protection, Faulty GFCI breaker?
|
ELE16-01128
| Electrical Rough-In | 5/18/2016 | 5/19/2016 | 5/19/2016 10:15:46 AM | A | PASS |
|
|
Justin Hamby Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Listed LED lettering rough-in ok
|
ELE16-01582
| Electrical Rough-In | 5/18/2016 | 5/19/2016 | 5/19/2016 9:09:16 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Barbara Szurgot rough-in ok cover kitchen/dinning area only
|