BLD15-00923
| BLD-Aging Inspection | 5/19/2016 | 5/19/2016 | 5/20/2016 2:05:22 PM | | PASS |
|
|
|
BLD14-03071
| BLD-Framing/Rough-in | 5/19/2016 | 5/19/2016 | 5/20/2016 1:34:08 PM | P | FAIL |
|
|
Work in progress on 1st, 2nd and 3rd. floors. Needs to fireblock fur downs, Provide the hat channel and additional layer of 5/8 type x rock to complete the floor ceiling assembly above fur downs. Provide 5/8 type x rock behind tub/shower stalls. Needs to box out washer boxes as well.
|
BLD14-03071
| BLD-Wall Bracing | 5/19/2016 | 5/19/2016 | 5/20/2016 1:29:22 PM | P | FAIL |
|
|
Needs to install all exterior and interior floor to floor straps, complete the sheating from interior shear walls on 3rd floor to underneath side of roof deck and provide the kicker supprts as per the approved plans. Also noted ares on interior shear walls not yet attached.
|
BLD15-04490
| BLD-Framing/Rough-in | 5/19/2016 | 5/19/2016 | 5/19/2016 4:54:41 PM | P | DEFR |
|
|
Shell Framing Inspection Phone #: ###-#### Inspection requested via web by Mike McHargue
|
BLD16-00672
| BLD-Foundation | 5/19/2016 | 5/19/2016 | 5/19/2016 4:07:06 PM | P | PASS |
|
|
Kay Phone #: ###-####
|
BLD16-01160
| BLD-Framing/Rough-in | 5/19/2016 | 5/19/2016 | 5/19/2016 2:06:24 PM | P | FAIL |
|
|
Phone #: 2085015747 >> Inspection requested via mobile web by Tom. Complete lateral bracing on T02 truss. Complet nailing off web of 2ply T15 truss per the truss engineering. Foam seal top plate and OSB at gas pipe penetration. Provide purlin on either side og T12A trusses on top chord twords heel were sheathing has been left short. Need additional blocking on hangars on two T12 trusses to comply with hangar listing. Correction notice issued. Ok to insulate.
|
BLD16-00926
| BLD-Conference | 5/19/2016 | 5/19/2016 | 5/19/2016 1:02:32 PM | P | DONE |
|
|
stop by project to check on progress, all MEP rough in inspections are completed. Framing is completed and majority covered. Also noted clearance issue with restroom door, side approach latch side, pull. Aslo noted elevated platform constructed that is not on plans. Tenant is removing some shhet rock for inspection, moving door to meet min clearance and will insulate under platform and then call in for frming inspection.
|
BLD16-00109
| BLD-Wall Bracing | 5/19/2016 | 5/19/2016 | 5/19/2016 12:45:57 PM | P | PASS |
|
|
Brett Phone #: ###-####
|
BLD14-03071
| BLD-Framing/Rough-in | 5/18/2016 | 5/19/2016 | 5/19/2016 12:44:10 PM | A | CANC |
|
|
Pat Phone #: ###-####-please call prior to meet. Moved to pm.
|
BLD16-00591
| BLD-Ceiling Grid Inspection | 5/19/2016 | 5/19/2016 | 5/19/2016 10:56:40 AM | A | NR |
|
|
Mike, Can we get a partial inspection for the front sales area grid (large portion) as we are waiting for a light for the hallway back in the rear. We do have approval to cover from electrical on that section. Phone #: ###-#### Inspection requested via web by Andrew George. Still needs mech. and fire sprinkler rough in inspections.
|
BLD15-03823
| BLD-Final | 5/18/2016 | 5/19/2016 | 5/19/2016 10:01:27 AM | A | PASS |
|
|
Hamish Phone #: ###-####. All issues resolved. Ok for perm occ.
|
BLD16-01327
| BLD-Final | 5/18/2016 | 5/19/2016 | 5/19/2016 9:43:10 AM | A | PASS |
|
|
Vera Phone #: ###-####
|
BLD16-01327
| DOC - Permit Finaled | 5/19/2016 | 5/19/2016 | 5/19/2016 9:42:50 AM | P | PASS |
|
|
|
BLD16-00451
| BLD-Final | 5/18/2016 | 5/19/2016 | 5/19/2016 9:25:39 AM | A | PASS |
|
|
James Phone #: ###-####. Issue resolved. ok for perm occ.
|
BLD14-03179
| BLD-Final | 5/18/2016 | 5/19/2016 | 5/19/2016 8:32:05 AM | A | PASS |
|
|
Please call in advance. Thx. Phone #: ###-#### Inspection requested via web by Scott Zierler
|
BLD14-03179
| DOC - Permit Finaled | 5/19/2016 | 5/19/2016 | 5/19/2016 8:31:48 AM | P | PASS |
|
|
|
BLD14-03178
| BLD-Final | 5/18/2016 | 5/19/2016 | 5/19/2016 8:31:00 AM | A | PASS |
|
|
Please call in advance. Thx. Phone #: ###-#### Inspection requested via web by Scott Zierler
|
BLD14-03178
| DOC - Permit Finaled | 5/19/2016 | 5/19/2016 | 5/19/2016 8:30:29 AM | P | PASS |
|
|
|