Inspections for the day of: Thursday, May 19, 2016.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC15-01227 General Inspection5/19/20165/19/20165/20/2016 4:39:06 PM PASS
No activity. No violations.
ESC16-00353 General Inspection5/19/20165/19/20165/19/2016 3:47:18 PMPPASS
Road footprint and parcels have been graded. Temporary sediment control wattles have been installed. The has been no hydomulching or tacifier applied at this point.

Permit sign posted with eNOI, SWPPP information in mail box.

No trackout or evidence of sediment discharges, BMPs are working. Approved.
ESC15-00659 General Inspection5/19/20165/19/20165/19/2016 3:04:43 PM PASS
Home complete and occupied. Very small yard to be landscaped by homeowner. Temp BMPs installed below the home for Somerset Village will be covered under ESC11-00879 (SV main permit with Jayo Const)
ESC15-00659 DOC - Permit Finaled5/19/20165/19/20165/19/2016 3:02:55 PMPPASS
ESC16-00122 General Inspection5/19/20165/19/20165/19/2016 2:35:52 PMPPASS
WIP. Flat lot. Vegetated perimeter with no surface water adajacent to site. Permit posted, construction entrance installed. No trackout or discharges.
ESC04-01581 DOC - Permit Finaled5/19/20165/19/20165/19/2016 2:34:30 PMPPASS
old expired permit in system. no inspection
ESC04-00407 DOC - Permit Finaled5/19/20165/19/20165/19/2016 2:34:11 PMPPASS
old expired permit in system. no inspection
ESC04-00337 DOC - Permit Finaled5/19/20165/19/20165/19/2016 2:33:28 PMPPASS
old expired permit in system. no inspection
ESC03-01619 DOC - Permit Finaled5/19/20165/19/20165/19/2016 2:33:20 PMPPASS
old expired permit in system. no inspection
ESC14-01063 General Inspection5/3/20165/19/20165/19/2016 2:32:40 PMPPASS
No construction activity. Appears precipitation was very light in this area compared to the others. No significant sources of sediment runoff. Storm drain inlet protection is in good condtion and lined concrete washout provided for SFHs active in phase 7.

Lots in phase 8 to be re-graded before final plat per RP Jill. No violations observed. Hillside vegetating very well.
ESC15-01612 Random Inspection5/19/20165/19/20165/19/2016 1:07:09 PMPPART
Rain event and work on bank in front of house caused some sediment runoff from site.

RP shoveled mud and sweep dirt off of the sidewalk back to site.

Corrective action needed:
- clean out mud/sediment trapped at the sediment filter mat.
- change out filter mat
ESC15-01091 BMP Violation5/19/20165/19/20165/19/2016 1:02:00 PMPFAIL
Corrections needed, sediment being carried off site to sidewalk and gutter.

1. Need to install sediment control wattle along the upper portions of the site along the sidewalk where stormwater is carrying sediment offsite.
2. Clean out receiving stormdrain below site and install sediment protection
ESC13-01279 General Inspection5/19/20165/19/20165/19/2016 12:52:51 PM PASS
No earthwork occuring at this time. Crews working on interiors on track of home on east side of Caddis. BMPs installed, no trackout or turbid discharges off site.
ESC15-01056 Aging Inspection5/19/20165/19/20165/19/2016 11:58:09 AM PASS
WIP. Needs landscaping/stabilization. Subdivsion BMPs installed. Approved.
ESC15-01058 Aging Inspection5/19/20165/19/20165/19/2016 11:56:55 AM PASS
needs final stabilization. No violations.
ESC16-00494 Site Preparation5/19/20165/19/20165/19/2016 11:25:38 AMAPART
Yellow card on site Inspection requested via web by Erby Gonzales

Need to post yellow ESC sign in front of project. WIP. Will inform RP. No other violations/issues in RH#6
ESC15-01225 General Inspection5/19/20165/19/20165/19/2016 10:09:14 AM PASS
Construction is complete. Hillside not yet fully vegetated and BLD still open. Observed that the disturbed area has been re-vegetated by noxious weed and advised pool company to alert homeowners.
ESC16-00560 Site Preparation5/18/20165/19/20165/19/2016 10:00:15 AMAPASS
James Phone #: ###-####

Pool installation in landscaped backyard. Flat area, low risk. RP familiar with ESC permit conditions & rules
ESC15-00660 General Inspection5/19/20165/19/20165/19/2016 9:54:52 AM PASS
Near completion. Landscaping crew onsite. No trackout, runoff on culdesac is not turbid- DI bag installed. Rear hilside below pool has had vegetation preserved, no erosion or sediment on road below.
ESC15-01428 General Inspection5/19/20165/19/20165/19/2016 9:30:25 AMPPASS
WIP. Portable concrete washout was used for driveway pour. No trackout or muddy runoff. Trash contained, RP onsite. Approved
ESC15-01004 General Inspection5/19/20165/19/20165/19/2016 9:21:47 AM PASS
Vertical construction in progress. Sediment and materials contained within pre-existing curbs that were pres No trackout from site. DIs have sediment protection, which is filtering street runoff.
ESC15-00627 General Inspection5/19/20165/19/20165/19/2016 7:54:47 AM PASS
No erosion or sediment runoff issues at site during any ESC inspection. No inspection activity conducted on any permit in over 6 months. No further ESC inspections necessary - permit expired.