Inspections for the day of: Wednesday, May 2, 2018.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM16-01473 PLM-Aging Inspection5/2/20185/2/20185/3/2018 11:50:05 AM PASS
PLM18-01779 Water Heater Final5/1/20185/2/20185/2/2018 4:39:59 PMPPASS
tenant is working from home all day on Wednesday and is expecting afternoon inspection .i am thinking we will be finished up about 1130.
please call me if there is any issues Phone #: ###-#### Inspection requested via web by Charles Lively
PLM18-01710 Final5/2/20185/2/20185/2/2018 4:21:59 PMPPASS
It''s ready anytime, Brian Scoles is also doing a HVAC final. Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek
PLM17-04438 Final5/2/20185/2/20185/2/2018 3:52:00 PMPPASS
Phone #: ###-#### Inspection requested via web by David Scaggs
PLM17-04437 Final5/2/20185/2/20185/2/2018 3:51:44 PMPPASS
Phone #: ###-#### Inspection requested via web by David Scaggs
PLM18-00749 Final5/2/20185/2/20185/2/2018 3:12:02 PMPPASS
Chema Phone #: ###-####
PLM18-01691 Plumbing Rough-in5/1/20185/2/20185/2/2018 2:25:56 PMPFAIL
JOB # 19694 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes.
Water test failed. Defective water gauge.
Add a cleanout to the aw.
PLM18-01793 Water and/or Sewer5/2/20185/2/20185/2/2018 2:03:29 PMPPASS
Phone #: ###-#### Inspection requested via web by phil duman
PLM18-01793 DOC - Permit Finaled5/2/20185/2/20185/2/2018 2:02:53 PMPPASS
PLM18-01778 Plumbing Rough-in5/1/20185/2/20185/2/2018 11:37:02 AMAPASS
Phone #: ###-#### Inspection requested via web by Chris Field
PLM18-01084 Final5/2/20185/2/20185/2/2018 10:42:02 AMAFAIL
The contractor has completed and passed all their work; this permit is being held for tenant requirments.
I spoke with the owner and explained again about the carbonator and ice tea maker needing to be separated. I also spoke to Coke and they claim they will perform the work asap. I will check back next week.
PLM18-01778 Final5/2/20185/2/20185/2/2018 10:38:41 AMACANC
PLM17-03541 Plumbing Rough-in5/1/20185/2/20185/2/2018 10:06:58 AMAPASS
BRAD IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER.
East cooridor water piping and both rest rooms.
PLM18-01688 Water and/or Sewer4/30/20185/2/20185/2/2018 9:43:54 AMAPEND
Phone #: ###-#### Inspection requested via web by robert seymour
PLM18-01688 DOC - Permit Finaled5/2/20185/2/20185/2/2018 9:41:51 AMPPASS
PLM18-01484 Plumbing Rough-in5/1/20185/2/20185/2/2018 8:50:48 AMAFAIL
Phone #: ###-#### Inspection requested via web by Tarah Young.
1. Add an 1-1/2" cleanout to the a/w vent.
2. The horizontal wet vent in the upstairs bath; The w.c. must be the furthest downstream fixture.
3. The downstairs:
a. 1-1/2" trap arm is too long and not vented properly.
b. W.C not vented.
PLM18-01484 Water and/or Sewer5/1/20185/2/20185/1/2018 10:22:00 PMACANC
Phone #: ###-#### >> Inspection requested via web by Tarah Young Inspection cancelled from web by: Tarah Young