ELE08-00893
| Final | 5/20/2008 | 5/20/2008 | 5/20/2008 3:47:35 PM | A | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ok bad gfci N end 3 bed rm unit
|
ELE08-01315
| Electrical Rough-In | 5/20/2008 | 5/20/2008 | 5/20/2008 3:41:25 PM | P | PART |
|
|
Neal ###-####///please call for access info walls and u/g ok
|
ELE08-01268
| Permanent Service | 5/20/2008 | 5/20/2008 | 5/20/2008 2:15:14 PM | P | PART |
|
|
###-#### - corey ###-#### office when finished p/s u/g rec. ok
|
ELE08-01268
| Final | 5/20/2008 | 5/20/2008 | 5/20/2008 2:14:55 PM | P | PASS |
|
|
###-#### - corey ###-#### office when finished ok
|
ELE08-00956
| Permanent Service | 5/19/2008 | 5/20/2008 | 5/20/2008 1:16:54 PM | P | PASS |
|
|
This inspection is for a 200 amp service change on a home that is being remodeled. Tom ###-#### Phone #: ###-#### Internet Inspection Request from: Emmet Bushman told contr about recept spacing for countertops in kit, p/s u/g rec. ok
|
ELE08-01307
| Rough-In Permanent Service | 5/19/2008 | 5/20/2008 | 5/20/2008 12:40:58 PM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Tracy Robertson r/i ok p/s u/g new ok
|
ELE08-01008
| Final | 5/19/2008 | 5/20/2008 | 5/20/2008 11:40:57 AM | A | PASS |
|
|
Patio cover lighting. Phone #: ###-#### Internet Inspection Request from: Lloyd Looney ok
|
ESC08-00330
| Site Preparation | 5/20/2008 | 5/20/2008 | 5/20/2008 10:33:01 AM | A | PART |
|
|
card posted
|
ELE08-01227
| Electrical Rough-In | 5/19/2008 | 5/20/2008 | 5/20/2008 10:30:24 AM | A | FAIL |
|
|
steve Phone #: ###-#### called corr update permit for 3 rms, 210.52(A&B) required outlet for old and new walls shall not use SABC for new office created from old din rm
|
ELE08-01244
| Conference | 5/20/2008 | 5/20/2008 | 5/20/2008 10:28:45 AM | A | DONE |
|
|
300.4 nail plates and 11/4" for cables, 210.52(A&B) required outlets for wall space new and old wall of kit and liv rm, shall not use SABC for micro wave D W disposal , only what code allows shall be on SABC, 250.140 shall use 4 wire for new oven, 314.16 box fill adjustible boxes in kit, called
|
ESC08-00376
| Site Preparation | 5/20/2008 | 5/20/2008 | 5/20/2008 10:24:37 AM | A | PART |
|
|
card posted site ok
|
ELE08-01244
| Electrical Rough-In | 5/19/2008 | 5/20/2008 | 5/20/2008 10:12:11 AM | A | FAIL |
|
|
tony - please call for access Phone #: see added conference
|
ELE08-01295
| Permanent Service | 5/19/2008 | 5/20/2008 | 5/20/2008 8:59:54 AM | A | PASS |
|
|
re-inspection on 200amp permanent power pole Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe p/s o/h new ok
|
ELE08-01295
| Final | 5/20/2008 | 5/20/2008 | 5/20/2008 8:59:38 AM | A | PASS |
|
|
re-inspection on 200amp permanent power pole Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe ok
|
ELE08-00911
| Final | 5/20/2008 | 5/20/2008 | 5/20/2008 8:23:27 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Dan Surerus 210.52(A) needs outlet for wall space between bath and closet doors, check clearence closet fixture if it is incandescent, 410.8 also needs service change for proper size house calcs out over 100 amp contr said called
|
ELE08-01268
| Final | 5/20/2008 | 5/20/2008 | 5/20/2008 7:47:13 AM | A | NR |
|
|
Electrical questions call Cory @ ###-####. Upgraded 100 amp panel to 200 amp Phone #: ###-#### Internet Inspection Request from: Yolanda Morris called contr (cory) he will call for p/s when ready
|
ELE08-00626
| ELE-Aging Inspection | 5/20/2008 | 5/20/2008 | 5/20/2008 7:25:27 AM | | DONE |
|
|
wsuc
|
ELE08-00589
| ELE-Aging Inspection | 5/20/2008 | 5/20/2008 | 5/20/2008 7:25:02 AM | | DONE |
|
|
wsuc
|
ELE08-00657
| ELE-Aging Inspection | 5/20/2008 | 5/20/2008 | 5/20/2008 7:24:26 AM | | DONE |
|
|
wsuc
|
ELE08-01268
| Electrical Rough-In | 5/19/2008 | 5/20/2008 | 5/19/2008 3:19:15 PM | A | CANC |
|
|
blanca Phone #: ###-#### Inspection cancelled from web by: Yolanda Morris
|