Inspections for the day of: Friday, May 20, 2011.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC11-00027 Random Inspection5/20/20115/20/20115/20/2011 3:54:14 PMPPASS
BLD11-00079 BLD-Other5/20/20115/20/20115/20/2011 3:54:01 PMPPART
CMU inspection please-Grout around 2:00--Gary Phone #: ###-#### placed w/si
ESC11-00090 Random Inspection5/20/20115/20/20115/20/2011 3:43:58 PMPPART
track out verbal will clean gutter.
BLD11-00348 BLD-Framing/Rough-in5/20/20115/20/20115/20/2011 3:38:15 PMPCANC
Rustin Phone #: ###-#### R703.6.3 Water-resistive barriers.
Water-resistive barriers shall be installed as required in Section R703.2 and, where applied over wood-based sheathing, shall include a water-resistive vapor-permeable barrier with a performance at least equivalent to two layers of Grade D paper. framer to verify if as framed at tall wall can be justified or if 8" oc stud spaciing per engineering to be corected.// load transpher of beams to ft north side of great rm west end.//nail top chord and webs of second floor girder truss t36/ fur out wing wall at furnce to 2x6 for r-19 insulation.
BLD10-02385 BLD-Final5/20/20115/20/20115/20/2011 1:46:46 PMPPASS
ted Phone #: ###-####
BLD10-02385 DOC - Permit Finaled5/20/20115/20/20115/20/2011 1:46:35 PMPPASS
BLD11-00351 BLD-Concrete5/19/20115/20/20115/20/2011 11:20:41 AMAPART
s line rebar appears ok per beam sch. rfi 33. work in progress.
BLD11-00549 BLD-Footing5/19/20115/20/20115/20/2011 10:02:42 AMANR
Bill Phone #: ###-####
ESC11-00153 Random Inspection5/20/20115/20/20115/20/2011 10:02:17 AMANR
ESC11-00150 Random Inspection5/20/20115/20/20115/20/2011 10:02:02 AMAPASS
BLD11-00537 BLD-Framing/Rough-in5/19/20115/20/20115/20/2011 10:01:45 AMAPASS
larry Phone #: ###-####