ELE14-01290
| Temporary Service | 5/20/2014 | 5/20/2014 | 5/20/2014 2:25:23 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey t/s u/g n ok
|
ELE14-01188
| Electrical Rough-In | 5/20/2014 | 5/20/2014 | 5/20/2014 1:57:38 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Matthew White met contractor, NEC 21.52 shall meet outlet spacing, shall provide 3-way switching and light for stairs to lower level, shall complete make-up, shall provide lighting outlet in storage spce as required
|
ELE12-00443
| Final | 5/20/2014 | 5/20/2014 | 5/20/2014 12:59:43 PM | P | PASS |
|
|
please give me 15 minutes lead time so I can meet and let you in the house Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin ok final
|
ELE13-01269
| Final | 5/20/2014 | 5/20/2014 | 5/20/2014 11:43:15 AM | P | PASS |
|
|
Contact: Brian Gee Phone #: ###-#### >> Inspection requested via web by Deb Gooden ok final
|
ELE11-00348
| ELE-Aging Inspection | 5/20/2014 | 5/20/2014 | 5/20/2014 10:19:29 AM | | DONE |
|
|
called to set up final
|
ELE14-00607
| Final | 5/19/2014 | 5/20/2014 | 5/20/2014 10:02:26 AM | A | NR |
|
|
Thanks! Phone #: ###-#### >> Inspection requested via web by Darryn Coburn called, painting garage, will recall
|
GCE14-00072
| GCE-Rough-In Permanent Service | 5/19/2014 | 5/20/2014 | 5/20/2014 9:51:52 AM | A | CANC |
|
|
Terry ###-#### called, wrong address, told contractor to recall after corrected request for inspection
|
GCE14-00053
| GCE-Rough-In | 5/19/2014 | 5/20/2014 | 5/20/2014 9:08:38 AM | A | PASS |
|
|
Ryan ###-#### ri ok
|
GCE14-00075
| GCE-Permanent Service | 5/19/2014 | 5/20/2014 | 5/20/2014 8:13:50 AM | A | FAIL |
|
|
Steve ###-#### inspection requested for as early as possible called, left correction notice, left card, NEC 230.2(E) shall provide permanent plaque at service disconnect, 110.22 shall identify disconnect, 110.12(A) shall close unused openings, BCC 4-05-24(D) shall provide access, fee due
|
GCE14-00075
| GCE-Inspection Hourly Charge | 5/20/2014 | 5/20/2014 | 5/20/2014 8:13:10 AM | P | PASS |
|
|
Steve ###-#### inspection requested for as early as possible 1 hour re-inspection fee
|