Inspections for the day of: Tuesday, May 20, 2014.
Number of inspections: 28
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD14-00361 BLD-Footing5/19/20145/20/20145/20/2014 4:46:57 PMPNR
Dane Phone #: ###-####. rescheduled for am.
BLD14-00322 BLD-Footing5/19/20145/20/20145/20/2014 4:46:16 PMPNR
Dane Phone #: ###-####. rescheduled for am.
BLD13-03527 BLD-Footing5/20/20145/20/20145/20/2014 3:23:45 PMPPASS
Phone #: ###-#### >> Inspection requested via web by James Larkin. interior thickend footings.
BLD13-03526 BLD-Footing5/20/20145/20/20145/20/2014 3:23:24 PMPPASS
Phone #: ###-#### >> Inspection requested via web by James Larkin. interior thickend footings.
BLD13-03525 BLD-Footing5/20/20145/20/20145/20/2014 3:22:58 PMPPASS
Phone #: ###-#### >> Inspection requested via web by James Larkin. interior thickend footings.
BLD13-03524 BLD-Footing5/20/20145/20/20145/20/2014 3:22:33 PMPCANC
Phone #: ###-#### >> Inspection requested via web by James Larkin
BLD13-03524 BLD-Footing5/20/20145/20/20145/20/2014 3:22:15 PMPPASS
Phone #: ###-#### >> Inspection requested via web by James Larkin. interior thickend footings.
BLD14-00457 BLD-Framing/Rough-in5/19/20145/20/20145/20/2014 2:25:55 PMPPASS
Brian Phone #: ###-####. Framing for area 1A ok.
BLD12-01135 BLD-Final5/19/20145/20/20145/20/2014 2:24:39 PMPPASS
Charley Cooper Phone #: ###-#### >> Inspection requested via web by Lorrie Ferris
BLD12-01135 DOC - Permit Finaled5/20/20145/20/20145/20/2014 2:24:27 PMPPASS
All issues have been resolved.
BLD12-01135 BLD-Blower Door Test Results5/20/20145/20/20145/20/2014 1:32:22 PMPDONE
3.6
ESC14-00041 Random Inspection5/20/20145/20/20145/20/2014 11:29:59 AMAPASS
BLD14-00135 BLD-Wall Bracing5/16/20145/20/20145/20/2014 11:29:39 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Paul Thompson
BLD14-00135 BLD-Conference5/19/20145/20/20145/20/2014 11:28:45 AMADONE
Phone #: ###-#### >> Inspection requested via web by Paul Thompson
BLD13-01934 BLD-Final5/19/20145/20/20145/20/2014 11:28:26 AMANR
Phone #: ###-#### >> Inspection requested via web by Paul Thompson. open mech permit. Needs final.
BLD13-03532 BLD-Wall cover5/19/20145/20/20145/20/2014 11:09:48 AMAPASS
Firewall assembly Phone #: ###-#### >> Inspection requested via web by Brian Stark. 3rd story ok.
BLD13-03533 BLD-Wall cover5/19/20145/20/20145/20/2014 11:08:39 AMAPASS
Firewall assembly Phone #: ###-#### >> Inspection requested via web by Brian Stark. 3rd story ok.
BLD13-03534 BLD-Wall cover5/19/20145/20/20145/20/2014 11:08:02 AMAPASS
Firewall assembly Phone #: ###-#### >> Inspection requested via web by Brian Stark. 3rd story ok.
BLD13-03535 BLD-Wall cover5/19/20145/20/20145/20/2014 11:07:01 AMAPASS
Firewall assembly Phone #: ###-#### >> Inspection requested via web by Brian Stark. 3rd story ok.
ESC13-01217 General Inspection5/20/20145/20/20145/20/2014 10:53:34 AMAPASS
BLD13-03360 BLD-Framing/Rough-in5/19/20145/20/20145/20/2014 10:53:15 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Brian Stark. Nail off top chord of 3ply truss in garage as per engineering. Box out electrical ground at 1hr. firewall with 5/8 type x rock.
ESC13-01216 General Inspection5/20/20145/20/20145/20/2014 10:49:38 AMAPASS
BLD13-03361 BLD-Framing/Rough-in5/19/20145/20/20145/20/2014 10:49:07 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Brian Stark. Install the 12 SDS screws on the T01 3ply as noted on truss engineering. "Box out" the electrical ground at 1hr. firewall with 5/8 type x rock. ok to insulate.
ESC13-01214 General Inspection5/20/20145/20/20145/20/2014 10:15:31 AMAPASS
BLD13-03363 BLD-Framing/Rough-in5/19/20145/20/20145/20/2014 10:15:03 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Brian Stark. Needs to provide bearing under 3ply LVL in garage. ok to insulate.
ESC13-01218 General Inspection5/20/20145/20/20145/20/2014 9:54:52 AMAPASS
BLD13-03359 BLD-Framing/Rough-in5/19/20145/20/20145/20/2014 9:54:29 AMAFAIL
Please call brian prior to inspection Phone #: ###-#### >> Inspection requested via web by Brian Stark. Complete lateral brace on T13 truss, "box out" elctrical ground on 1hr wall with 5/8 type x rock. ok to insulate.
MIS14-00108 BLD-Conference5/19/20145/20/20145/20/2014 9:16:31 AMAFAIL
complaint-building & electrical work being done w/o permits. Noted remodel wprk inside of house, removed and relocated walls, electrical work as well. Also noted plumbing work being done at detached accesory structure in backyard. A correction notice was issued to stop work, aplly for all required permits and have work inspected. Also notified electrical and plumbing inspectors.