ELE12-00913
| ELE-Aging Inspection | 5/21/2014 | 5/21/2014 | 5/27/2014 10:23:09 AM | | DONE |
|
|
left message
|
ELE12-02301
| ELE-Aging Inspection | 5/21/2014 | 5/21/2014 | 5/27/2014 10:19:37 AM | | DONE |
|
|
called but no way to leave message
|
ELE14-01301
| Temporary Service | 5/21/2014 | 5/21/2014 | 5/21/2014 3:18:36 PM | P | PASS |
|
|
ELE-INSPECTOR t/s u/g n ok
|
ELE14-00640
| Final | 5/20/2014 | 5/21/2014 | 5/21/2014 3:05:13 PM | P | FAIL |
|
|
ELE-INSPECTOR a/c cond. unit says max. breaker 25amp. lockoff on breaker for furnace needed. flash ring needed on kitchen pendant switch in tile backsplash.
|
ELE14-01071
| Electrical Rough-In | 5/20/2014 | 5/21/2014 | 5/21/2014 2:30:03 PM | P | PASS |
|
|
ELE-INSPECTOR phase 2, 2nd floor rough in walls n.east offices ok to cover
|
ELE14-00504
| Electrical Rough-In | 5/15/2014 | 5/21/2014 | 5/21/2014 2:12:30 PM | P | PASS |
|
|
Ceiling inspection. Jake is the contact his cell is ###-####. Phone #: ###-#### >> Inspection requested via web by Mike Basye rough in ceilings ok to cover
|
MIS14-00112
| ELE-Conference | 5/21/2014 | 5/21/2014 | 5/21/2014 12:28:43 PM | P | DONE |
|
|
meet Gorden Goldsmith with Boise fire dept. to look at electrical overhead wiring needing to be de energized because of garage fire. owner of residence says he will hire electrical contractor to separate electrical from house within 24 hrs of correction notice
|
ELE14-01124
| Electrical Rough-In | 5/21/2014 | 5/21/2014 | 5/21/2014 12:12:49 PM | A | FAIL |
|
|
ELE-INSPECTOR 334.30 secure nm cable min. every 4 1/2 feet above sub-panel in hall. 300.4D 11/4 min to nm cable from edge of framing. under subpanel and 1/0ser in kitchen. Exhaust fan not installed and waterbond ground needs to be connected.
|
ELE14-00910
| Final | 5/20/2014 | 5/21/2014 | 5/21/2014 11:39:51 AM | A | PASS |
|
|
ELE-INSPECTOR final ok
|
ELE14-00992
| Final | 5/21/2014 | 5/21/2014 | 5/21/2014 11:26:53 AM | A | FAIL |
|
|
ELE-INSPECTOR box extensions 314.20 in breakroom backsplash
|
ELE14-00817
| Final | 5/20/2014 | 5/21/2014 | 5/21/2014 10:58:32 AM | A | CANC |
|
|
ELE-INSPECTOR needed rough in insp.
|
ELE14-00817
| Electrical Rough-In | 5/21/2014 | 5/21/2014 | 5/21/2014 10:58:07 AM | P | PASS |
|
|
ELE-INSPECTOR rough in ok to cover house and garage
|
GCE14-00075
| GCE-Final | 5/21/2014 | 5/21/2014 | 5/21/2014 10:05:03 AM | P | PASS |
|
|
Joel Smith ###-#### call for access; installer will meet inspector final ok
|
ELE13-02849
| Electrical Rough-In | 5/19/2014 | 5/21/2014 | 5/21/2014 9:27:12 AM | A | CANC |
|
|
Contact is Alan Krishnek ###-#### Phone #: ###-#### >> Inspection requested via web by Scott Campbell cancelled as per alan
|
ELE14-00981
| Final | 5/20/2014 | 5/21/2014 | 5/21/2014 9:05:26 AM | A | PASS |
|
|
ELE-INSPECTOR final ok
|