MEC13-01566
| Mec-Aging Inspection | 5/21/2014 | 5/21/2014 | 5/21/2014 4:42:41 PM | | CANC |
|
|
NO CALLS
|
MEC14-01949
| Final | 5/21/2014 | 5/21/2014 | 5/21/2014 4:31:07 PM | P | NH |
|
|
Contact homeowner for access at ###-#### or ###-####. Phone #: ###-#### >> Inspection requested via web by Amanda Drake
|
MEC13-04874
| Final | 5/21/2014 | 5/21/2014 | 5/21/2014 3:57:55 PM | P | PASS |
|
|
MEC-INSPECTOR
|
MEC14-01950
| Final | 5/21/2014 | 5/21/2014 | 5/21/2014 2:55:25 PM | P | CANC |
|
|
Late PM please. Thanks. Phone #: ###-#### >> Inspection requested via web by April Thomas Inspection cancelled from web by: April Thomas
|
MEC14-01716
| Final | 5/20/2014 | 5/21/2014 | 5/21/2014 2:50:33 PM | P | FAIL |
|
|
jared Phone #: ###-#### - MAKE UP AIR INLETS NEED TO BE INSTALLED ON EXTERIOR WALLS DOWN LOW CLOSE TO THE FLOOR. ALL EXHAUST OUTLETS NEED TO BE INSTALLED UP HIGH CLOSE TO THE ROOF LINE. PER IMC 2009 502.16.1
|
MEC13-05287
| Pressure Test | 5/20/2014 | 5/21/2014 | 5/21/2014 1:50:39 PM | P | PART |
|
|
MEC-COM/RES INSPECTOR - LIGHT TEST FOR KITCHEN STUDIO HOOD GREASE DUCT IN SHAFT PASS.
|
MEC13-05287
| Rough-in | 5/20/2014 | 5/21/2014 | 5/21/2014 1:49:07 PM | P | PART |
|
|
MEC-COM/RES INSPECTORN - DUCT APPROVED FOR WRAP NORTH SIDE OF MULTI MEDIA SOFFIT.
|
MEC14-01417
| Final | 5/20/2014 | 5/21/2014 | 5/21/2014 11:52:16 AM | A | PASS |
|
|
MEC-INSPECTOR
|
MEC14-01108
| Final | 5/20/2014 | 5/21/2014 | 5/21/2014 11:17:04 AM | A | PASS |
|
|
THanks Phone #: ###-#### >> Inspection requested via web by Aaron Toomey
|
MEC14-00450
| Final | 5/19/2014 | 5/21/2014 | 5/21/2014 10:46:14 AM | A | PASS |
|
|
Please call Ted @ ###-#### 45 mins prior for flue testing. Thank you >> Inspection requested via web by MARGIE ROWE - 5LB FLUE PRESSURE PASS
|
MEC14-01493
| Conference | 5/20/2014 | 5/21/2014 | 5/21/2014 10:26:20 AM | A | DONE |
|
|
MEC-INSPECTOR
|
MEC14-01493
| Final | 5/21/2014 | 5/21/2014 | 5/21/2014 10:13:48 AM | A | PASS |
|
|
MEC-INSPECTOR
|
MEC14-01765
| Rough-in | 5/20/2014 | 5/21/2014 | 5/21/2014 10:03:39 AM | A | PASS |
|
|
Roy phone - ###-#### after 9:00 - 20LB GAS PRESSURE PASS, ROUGH IN
|
MEC14-01470
| Conference | 5/20/2014 | 5/21/2014 | 5/21/2014 9:42:47 AM | A | DONE |
|
|
9:00 am
|
MEC14-01882
| Rough-in | 5/20/2014 | 5/21/2014 | 5/21/2014 8:28:55 AM | A | PASS |
|
|
MEC-INSPECTOR
|
MEC14-01882
| Pressure Test | 5/20/2014 | 5/21/2014 | 5/21/2014 8:28:12 AM | A | PASS |
|
|
MEC-INSPECTOR -20LB GAS PRESSURE PASS
|
MEC14-00890
| Final | 5/20/2014 | 5/21/2014 | 5/21/2014 8:02:33 AM | A | PASS |
|
|
OLEG - ###-#### ACCESS CODE 3274
|