Inspections for the day of: Wednesday, May 21, 2014.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC13-00993 Aging Inspection5/21/20145/21/20145/21/2014 4:20:20 PM CANC
rescheduled for 5/22
ESC14-00046 General Inspection5/21/20145/21/20145/21/2014 4:16:23 PM PASS
Some work ongoing to stabilize upper parking level. No violations.
ESC14-00154 Site Preparation5/21/20145/21/20145/21/2014 2:37:10 PMPPASS
Met RP Clyde onsite to discuss project. Retaining wall soil that is excavated will be tested and used as backfill if possible.

There is 1 storm drain across the street that may required protection. No surface waters adjacent to site. Approved for construction. Home is under seperate ESC permit.
ESC13-00922 Aging Inspection5/21/20145/21/20145/21/2014 2:08:40 PM PASS
Finaled.
ESC13-00922 DOC - Permit Finaled5/21/20145/21/20145/21/2014 2:08:25 PMPPASS
House complete and landscaped. ESC conditions satisfied.
ESC13-01093 Site Preparation5/21/20145/21/20145/21/2014 2:01:30 PMPPASS
austin Phone #: ###-####

Permit posted. Access to site via alley, which is in good condition. In process of removing dried waste from washout.

Approved for construction.
ESC13-00684 General Inspection5/21/20145/21/20145/21/2014 1:57:41 PM PASS
Road is now paved. Working on the manholes for sewer and installing sidewalk along Warm Springs. Concrete trucks using lined washout on site.

Warm Springs should be swept along the frontage of the development when they clean the new road.

Site perimeter is well contained.
ESC13-00232 Site Final5/21/20145/21/20145/21/2014 1:34:42 PMPPASS
Clyde Phone #: ###-####

Finaled. See activity notes.
ESC13-00232 DOC - Permit Finaled5/21/20145/21/20145/21/2014 1:34:22 PMPPASS
ESC conditions satisfied. Strip of land under power pole will naturally seed itself. No further inspections needed. Trash container will be removed soon.
ESC14-00266 Site Preparation5/20/20145/21/20145/21/2014 11:42:26 AMAPASS
Dillon Phone #: ###-####



Permit posted, approved plans and ESC narrative on site. BMPs installed include downslope wattles, stabilized access, and concrete washout. Stormwater infrastructure has existing inlet protection.

Approved.
ESC14-00119 General Inspection5/21/20145/21/20145/21/2014 11:42:02 AM PASS
No exterior activity or disturbance. BLD and trade permits still active.
ESC14-00280 Complaint Inspection5/21/20145/21/20145/21/2014 10:40:12 AMPPART
Received complaint about ESC issues, noise, and parking issues at site:

No activity at time of inspection. Trench work for sewer/water utilities was not properly cleaned up at end of day yesterday. There is very limited space where driveway goes to parcel it should be noted.

Observations:

Some dirt tracked onto to the street from stockpiling/trenching activities.
No major trackout beyond entrance to site; No trash or other construction debris/material uncontained.

Permit posted.

Correction Notice posted; discussed corrections with RP Vince on phone.

Corrections:

1. Sweep up at end of each day or more as necessary.

2. Construction hours 6:30 AM-6:00 PM MF, 8:30-6 PM weekends.

3. Install watte or silt fence to protect neighbor's grass.

Due Thursday 5/22/2014 at 12 PM
ESC13-00144 General Inspection5/21/20145/21/20145/21/2014 9:35:40 AM PASS
ESC13-01247 General Inspection5/21/20145/21/20145/21/2014 9:18:00 AM PASS
Hillside stabilization still in progress but not yet complete. Construction is complete.
ESC13-01245 General Inspection5/21/20145/21/20145/21/2014 8:58:24 AM PASS
ESC13-00854 General Inspection5/21/20145/21/20145/21/2014 8:43:28 AM PASS