ELE19-01403
| Electrical Rough-In | 5/21/2020 | 5/21/2020 | 5/21/2020 3:42:02 PM | P | PASS |
|
|
I rough in inspection for device boxes and raceways in ramps pour 6-2. Phone #: ###-#### Inspection requested via web by John Mittleider Pour noted rough in ok cover
|
ELE20-01638
| Final | 5/21/2020 | 5/21/2020 | 5/21/2020 3:21:37 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rick Beckman Final ok
|
ELE20-01734
| Rough-In Permanent Service | 5/21/2020 | 5/21/2020 | 5/21/2020 2:46:49 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by michael hunt Needed rough in for house and garage only, service not ready
|
ELE20-01734
| Electrical Rough-In | 5/21/2020 | 5/21/2020 | 5/21/2020 2:46:34 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by michael hunt House panel on interior wall, informed a disconnecting means is required on exterior or interior immediately upon entering house as per 225.32. House and garage rough in ok cover.
|
ELE20-00601
| Final | 5/20/2020 | 5/21/2020 | 5/21/2020 2:04:19 PM | P | FAIL |
|
|
Shay *screened* Phone #: ###-#### 210.8(A)- All receptacle outlets installed in garage and outdoor locations shall have GFCI protection. 314.20- All boxes positioned 1/4" or more fron surface of wall shall have spark rings installed. forgot to list on correction but did inform verbally. 314.42- NM cable shall be protected from damage when entering a metal enclosure. Minisplit disconnect. 406.9(A)- Receptacle outlets located in damp or wet locations shall be WR type. Outdoor receptacles not protected from weather shall have in-use covers installed, west side and deck. 406.12(1)- All receptacle outlets required by 210.52 shall be tamper resistant type.
|
ELE20-01733
| Final | 5/21/2020 | 5/21/2020 | 5/21/2020 11:16:54 AM | A | PASS |
|
|
I wired A New Furnace In Garage And Disabled Old Wiring For Now Removed Electric Furnace. Home Owner Is Home And Garage Is Open For Inspection Phone #: ###-#### Inspection requested via web by jason shifflett Final ok
|
ELE20-01733
| Electrical Rough-In | 5/21/2020 | 5/21/2020 | 5/21/2020 11:09:06 AM | P | PASS |
|
|
I wired A New Furnace In Garage And Disabled Old Wiring For Now Removed Electric Furnace. Home Owner Is Home And Garage Is Open For Inspection Phone #: ###-#### Inspection requested via web by jason shifflett Added 15 amp 120 volt circuit for new gas furnace located adjacent to garage panel. Rough in ok.
|
ELE20-00908
| Final | 5/20/2020 | 5/21/2020 | 5/21/2020 10:51:50 AM | A | PASS |
|
|
Please call prior to arrival for access. Phone #: ###-#### Inspection requested via web by Patrick Paz Final ok
|
ELE20-01082
| Final | 5/20/2020 | 5/21/2020 | 5/21/2020 9:15:22 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rodney Monroe Final ok
|
ELE20-01081
| Final | 5/20/2020 | 5/21/2020 | 5/21/2020 9:00:42 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rodney Monroe Final ok
|
ELE20-01638
| Final | 5/20/2020 | 5/21/2020 | 5/21/2020 6:24:23 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Rick Beckman Inspection cancelled from web by: Rick Beckman
|