Inspections for the day of: Thursday, May 21, 2020.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-01403 Electrical Rough-In5/21/20205/21/20205/21/2020 3:42:02 PMPPASS
I rough in inspection for device boxes and raceways in ramps pour 6-2. Phone #: ###-#### Inspection requested via web by John Mittleider Pour noted rough in ok cover
ELE20-01638 Final5/21/20205/21/20205/21/2020 3:21:37 PMPPASS
Phone #: ###-#### Inspection requested via web by Rick Beckman Final ok
ELE20-01734 Rough-In Permanent Service5/21/20205/21/20205/21/2020 2:46:49 PMPCANC
Phone #: ###-#### Inspection requested via web by michael hunt
Needed rough in for house and garage only, service not ready
ELE20-01734 Electrical Rough-In5/21/20205/21/20205/21/2020 2:46:34 PMPPASS
Phone #: ###-#### Inspection requested via web by michael hunt
House panel on interior wall, informed a disconnecting means is required on exterior or interior immediately upon entering house as per 225.32.
House and garage rough in ok cover.
ELE20-00601 Final5/20/20205/21/20205/21/2020 2:04:19 PMPFAIL
Shay *screened* Phone #: ###-####
210.8(A)- All receptacle outlets installed in garage and outdoor locations shall have GFCI protection.
314.20- All boxes positioned 1/4" or more fron surface of wall shall have spark rings installed. forgot to list on correction but did inform verbally.
314.42- NM cable shall be protected from damage when entering a metal enclosure. Minisplit disconnect.
406.9(A)- Receptacle outlets located in damp or wet locations shall be WR type. Outdoor receptacles not protected from weather shall have in-use covers installed, west side and deck. 406.12(1)- All receptacle outlets required by 210.52 shall be tamper resistant type.
ELE20-01733 Final5/21/20205/21/20205/21/2020 11:16:54 AMAPASS
I wired A New Furnace In Garage And Disabled Old Wiring For Now Removed Electric Furnace. Home Owner Is Home And Garage Is Open For Inspection Phone #: ###-#### Inspection requested via web by jason shifflett
Final ok
ELE20-01733 Electrical Rough-In5/21/20205/21/20205/21/2020 11:09:06 AMPPASS
I wired A New Furnace In Garage And Disabled Old Wiring For Now Removed Electric Furnace. Home Owner Is Home And Garage Is Open For Inspection Phone #: ###-#### Inspection requested via web by jason shifflett
Added 15 amp 120 volt circuit for new gas furnace located adjacent to garage panel. Rough in ok.
ELE20-00908 Final5/20/20205/21/20205/21/2020 10:51:50 AMAPASS
Please call prior to arrival for access. Phone #: ###-#### Inspection requested via web by Patrick Paz Final ok
ELE20-01082 Final5/20/20205/21/20205/21/2020 9:15:22 AMAPASS
Phone #: ###-#### Inspection requested via web by Rodney Monroe Final ok
ELE20-01081 Final5/20/20205/21/20205/21/2020 9:00:42 AMAPASS
Phone #: ###-#### Inspection requested via web by Rodney Monroe Final ok
ELE20-01638 Final5/20/20205/21/20205/21/2020 6:24:23 AMACANC
Phone #: ###-#### >> Inspection requested via web by Rick Beckman Inspection cancelled from web by: Rick Beckman