BLD08-00643
| BLD-Framing/Rough-in | 5/22/2008 | 5/22/2008 | 5/22/2008 4:34:31 PM | P | FAIL |
|
|
jay Phone #: ###-####TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDSa
STUD SIZE (inches) BEARING WALLS NONBEARING WALLS Laterally unsupported stud heighta (feet) Maximum spacing when supporting roof and ceiling only (inches) Maximum spacing when supporting one floor, roof and ceiling (inches) Maximum spacing when supporting two floors, roof and ceiling (inches) Maximum spacing when supporting one floor only (inches) Laterally unsupported stud heighta (feet) Maximum spacing (inches) 2 × 3b — — — — — 10 16 2 × 4 10 24 16 — 24 14 24 3 × 4 10 24 24 16 24 14 24 2 × 5 10 24 24 — 24 16 24 2 × 6 10 24 24 16 24 20 24 max stud spacing 24 on 2x6/ 16 on 2x4
floor hanger hangers over nailled justify.
|
BLD08-00610
| BLD-Framing/Rough-in | 5/22/2008 | 5/22/2008 | 5/22/2008 4:07:41 PM | P | FAIL |
|
|
jay Phone #: ###-#### b3 girder truss required to be 3 ply per engineering/ hangers over shot void mfg. listing c/n posted.
|
BLD08-00049
| BLD-Final | 5/22/2008 | 5/22/2008 | 5/22/2008 3:31:20 PM | P | PASS |
|
|
jay Phone #: ###-####
|
BLD08-00049
| DOC - Permit Finaled | 5/22/2008 | 5/22/2008 | 5/22/2008 3:31:10 PM | P | PASS |
|
|
|
BLD07-02934
| BLD-Final | 5/22/2008 | 5/22/2008 | 5/22/2008 2:30:15 PM | P | PASS |
|
|
corey Phone #: ###-####
|
BLD08-00344
| BLD-Framing/Rough-in | 5/22/2008 | 5/22/2008 | 5/22/2008 2:00:54 PM | P | PASS |
|
|
kyle Note: cover for restrooms Phone #: ###-####
|
BLD08-00127
| BLD-Framing/Rough-in | 5/21/2008 | 5/22/2008 | 5/22/2008 11:31:38 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 5/21/2008 at 4:52:52 PM. Contact: ###-####.ceilling and draftstop ok.
|
BLD07-02405
| BLD-Conference | 5/21/2008 | 5/22/2008 | 5/22/2008 11:31:03 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 5/21/2008 at 4:55:17 PM. Contact: ###-####.
|
ESC07-01185
| Random Inspection | 5/22/2008 | 5/22/2008 | 5/22/2008 11:30:42 AM | A | PASS |
|
|
|
BLD07-02854
| BLD-Other | 5/21/2008 | 5/22/2008 | 5/22/2008 8:04:50 AM | A | PASS |
|
|
jean Note: rebar on retaining wall Phone #: ###-#### east section ok
|
ESC07-01379
| Random Inspection | 5/22/2008 | 5/22/2008 | 5/22/2008 8:04:24 AM | A | PASS |
|
|
|
BLD08-00758
| BLD-Framing/Rough-in | 5/21/2008 | 5/22/2008 | 5/21/2008 3:48:34 PM | A | PASS |
|
|
jeff Phone #: ###-####
|