Inspections for the day of: Thursday, May 22, 2008.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD08-00643 BLD-Framing/Rough-in5/22/20085/22/20085/22/2008 4:34:31 PMPFAIL
jay Phone #: ###-####TABLE R602.3(5)
SIZE, HEIGHT AND SPACING OF WOOD STUDSa

STUD SIZE
(inches) BEARING WALLS NONBEARING WALLS
Laterally unsupported stud heighta
(feet) Maximum spacing when supporting roof and ceiling only
(inches) Maximum spacing when supporting one floor, roof and ceiling
(inches) Maximum spacing when supporting two floors, roof and ceiling
(inches) Maximum spacing when supporting one floor only
(inches) Laterally unsupported stud heighta
(feet) Maximum spacing
(inches)
2 × 3b — — — — — 10 16
2 × 4 10 24 16 — 24 14 24
3 × 4 10 24 24 16 24 14 24
2 × 5 10 24 24 — 24 16 24
2 × 6 10 24 24 16 24 20 24
max stud spacing 24 on 2x6/ 16 on 2x4

floor hanger hangers over nailled justify.
BLD08-00610 BLD-Framing/Rough-in5/22/20085/22/20085/22/2008 4:07:41 PMPFAIL
jay Phone #: ###-#### b3 girder truss required to be 3 ply per engineering/ hangers over shot void mfg. listing c/n posted.
BLD08-00049 BLD-Final5/22/20085/22/20085/22/2008 3:31:20 PMPPASS
jay Phone #: ###-####
BLD08-00049 DOC - Permit Finaled5/22/20085/22/20085/22/2008 3:31:10 PMPPASS
BLD07-02934 BLD-Final5/22/20085/22/20085/22/2008 2:30:15 PMPPASS
corey Phone #: ###-####
BLD08-00344 BLD-Framing/Rough-in5/22/20085/22/20085/22/2008 2:00:54 PMPPASS
kyle Note: cover for restrooms Phone #: ###-####
BLD08-00127 BLD-Framing/Rough-in5/21/20085/22/20085/22/2008 11:31:38 AMAPASS
Scheduled by a contractor via Hello! on 5/21/2008 at 4:52:52 PM. Contact: ###-####.ceilling and draftstop ok.
BLD07-02405 BLD-Conference5/21/20085/22/20085/22/2008 11:31:03 AMAPASS
Scheduled by a contractor via Hello! on 5/21/2008 at 4:55:17 PM. Contact: ###-####.
ESC07-01185 Random Inspection5/22/20085/22/20085/22/2008 11:30:42 AMAPASS
BLD07-02854 BLD-Other5/21/20085/22/20085/22/2008 8:04:50 AMAPASS
jean Note: rebar on retaining wall Phone #: ###-#### east section ok
ESC07-01379 Random Inspection5/22/20085/22/20085/22/2008 8:04:24 AMAPASS
BLD08-00758 BLD-Framing/Rough-in5/21/20085/22/20085/21/2008 3:48:34 PMAPASS
jeff Phone #: ###-####