Inspections for the day of: Monday, May 22, 2017.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-01860 Final5/22/20175/22/20175/22/2017 4:09:11 PMPNH
Phone #: ###-#### Inspection requested via web by Marisa Hone- no one home- left notice on front door
MEC17-01908 Rough-in5/22/20175/22/20175/22/2017 3:40:57 PMPPASS
R/I ok for range hood
MEC17-01908 Final5/22/20175/22/20175/22/2017 3:40:05 PMPCANC
Would like Mid PM and call when on way. Thank you! Phone #: ###-#### Inspection requested via web by Xanti Berria- this should have been R/I
MEC17-01908 Pressure Test5/22/20175/22/20175/22/2017 3:34:50 PMPPASS
Would like Mid PM and call when on way. Thank you! Phone #: ###-#### Inspection requested via web by Xanti Berria- 20lb gas pass
MEC17-01905 Rough-in5/22/20175/22/20175/22/2017 2:54:02 PMPPASS
Phone #: ###-#### Inspection requested via web by Frank Marturello
MEC17-01905 Pressure Test5/22/20175/22/20175/22/2017 2:51:41 PMPPASS
Phone #: ###-#### Inspection requested via web by Frank Marturello- 20lb gas pass
MEC16-04590 Rough-in5/19/20175/22/20175/22/2017 2:20:06 PMPPASS
Please call Arthur, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum- R/I ok on unit heaters
MEC17-01635 Rough-in5/22/20175/22/20175/22/2017 1:42:55 PMPFAIL
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- need make up air for range hood- need transfer grill in laundry room for whole house ventilation- fresh air can not come from roof- need to draw exhaust air fir HRV from living space per manufactures installation diagram- left correction notice on front window- gave builder ok to spray foam exterior walls only
MEC17-01635 Pressure Test5/22/20175/22/20175/22/2017 1:39:31 PMPPASS
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- 20lb gas pass
MEC17-01756 Final5/19/20175/22/20175/22/2017 11:13:27 AMAFAIL
Please call Jeff Creek for access info ###-####. Phone #: ###-#### Inspection requested via web by Andrea Creek- 5lb flue test on water heater and furnace fail- line set outdoors needs uv protection-
MEC17-01546 Rough-in5/19/20175/22/20175/22/2017 10:36:29 AMAPASS
Re-Inspection of the Rough In Phone #: ###-#### Inspection requested via web by Frank Marturello
MEC17-00938 Final5/19/20175/22/20175/22/2017 10:05:05 AMAPASS
BRAXTON ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
MEC17-01079 Final5/22/20175/22/20175/22/2017 9:51:10 AMAPASS
MEC17-00901 Final5/19/20175/22/20175/22/2017 9:11:39 AMANR
Field Super Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC17-01836 Final5/19/20175/22/20175/22/2017 8:50:58 AMAPASS
Kelly (home owner) only has limited time he can be home to let someone in. He has to leave the house by 930am. If this time doesn''t work we will have to reschedule. Thank you!! Phone #: ###-#### Inspection requested via web by Devony Bullard