ELE17-01963
| ELE-Aging Inspection | 5/22/2019 | 5/22/2019 | 5/23/2019 4:27:41 PM | | FAIL |
|
|
Final inspection required.
|
ELE19-01316
| Electrical Rough-In | 5/22/2019 | 5/22/2019 | 5/22/2019 3:08:28 PM | P | PASS |
|
|
Late afternoon if possible. Phone #: ###-#### Inspection requested via web by Kevin Burke Called and attached to BLD18-03116. Units 103, 104, 203, 204, 303, 304. 2nd 6 from south rough in ok cover.
|
ELE19-00734
| Final | 5/22/2019 | 5/22/2019 | 5/22/2019 2:08:35 PM | P | FAIL |
|
|
if no answer at above number call ###-#### Phone #: ###-#### Inspection requested via web by Robert Murray 314.16- Island receptacle box is an 8 cubic inch box with 11.25 cubic inch of conductor installed.
|
ELE19-00619
| Final | 5/22/2019 | 5/22/2019 | 5/22/2019 2:05:58 PM | P | FAIL |
|
|
if no answer at above number call ###-#### Phone #: ###-#### Inspection requested via web by Robert Murray 314.16- Island receptacle box is an 8 cubic inch box with 11.25 cubic inch of conductor installed. 314.25- All boxes shall have covers. Microwave not trimmed.
|
ELE19-01875
| Rough-In Permanent Service | 5/21/2019 | 5/22/2019 | 5/22/2019 1:19:01 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Same Electric p/s o/h rec ok
|
ELE19-01813
| Rough-In Permanent Service | 5/22/2019 | 5/22/2019 | 5/22/2019 12:29:49 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Wires coiled in walls above fireplace and center wall to right of fireplace and level 2 attic boxes trimmed on rough in. Rough in ok cover p/s u/g n ok
|
ELE18-04013
| Final | 5/21/2019 | 5/22/2019 | 5/22/2019 11:28:20 AM | A | FAIL |
|
|
Roof Top units ready for final. Jason is our contact at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Kelly Felin 408.4- Circuit directory shall be accurately labeled as to which unit supplied with unit marked with identification of circuit or individual unit. 440.4- Overcurrent protection shall not exceed value given on name plate.
|
ELE19-01647
| Electrical Rough-In | 5/20/2019 | 5/22/2019 | 5/22/2019 10:36:34 AM | A | PASS |
|
|
Call foreman, Brad Hallman, one hour prior to arrival to coordinate. Phone #: ###-#### Inspection requested via web by Rob Maes Silfab is the solar panel of record and the brand installed. Listings confirmed rough in ok.
|
ELE19-01749
| Electrical Rough-In | 5/21/2019 | 5/22/2019 | 5/22/2019 10:21:23 AM | A | FAIL |
|
|
Malcolm Phone #: ###-#### 210.11- Garage receptacle circuit shall have no other outlets. Garage lighting on with receptacles and 14 ga. wire installed as jumpers between lights and travellers in garage.
|
ELE19-01458
| Permanent Service | 5/21/2019 | 5/22/2019 | 5/22/2019 9:47:11 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by jamie berg p/s o/h n ok
|
ELE19-01682
| Final | 5/21/2019 | 5/22/2019 | 5/22/2019 9:32:18 AM | A | PASS |
|
|
call first, ###-#### Phone #: ###-#### Inspection requested via web by PAT MILLER Final ok
|
ELE19-01883
| Permanent Service | 5/21/2019 | 5/22/2019 | 5/22/2019 9:11:53 AM | A | FAIL |
|
|
Power off for over one year. Need inspection to turn power on. Please call Ryan for lock box code ###-#### Phone #: ###-#### Inspection requested via web by Ryan Schaffer 110.26(A)- Minimum work space shall be provided for meter base and both service disconnecting means of 30" wide and 36" deep. Remove evergreens to minimum required. 250.20- Services operating at 50 to 1000 volts shall be grounded. Unable to verify grounding electrode system and grounding electrode conductor installation. Meter base sealed and they are not located in either disconnecting means.
|
ELE19-01886
| Temporary Service | 5/22/2019 | 5/22/2019 | 5/22/2019 8:16:08 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Heideman t/s u/g n ok
|