MEC19-00509
| Final | 5/22/2019 | 5/22/2019 | 5/22/2019 3:34:55 PM | P | PASS |
|
|
Inspection requested via web by jeff jedlick - final ok
|
MEC19-02061
| Rough-in | 5/22/2019 | 5/22/2019 | 5/22/2019 2:54:35 PM | P | FAIL |
|
|
- crawl is not finished yet - still need city stamped man J onsite
|
MEC19-02062
| Rough-in | 5/22/2019 | 5/22/2019 | 5/22/2019 2:48:45 PM | P | CANC |
|
|
Inspection requested via web by william kerwin - already passed R/I inspection
|
MEC19-02066
| Pressure Test | 5/21/2019 | 5/22/2019 | 5/22/2019 2:25:19 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Arielle Hendricks - 20lb gas pressure test ok - tagged meter location - will need to see air balance report and duct blast test for final
|
MEC19-01966
| Pressure Test | 5/21/2019 | 5/22/2019 | 5/22/2019 2:03:56 PM | P | PASS |
|
|
Call Jason @ ###-#### with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire - 5lb flue pressure test ok - 20lb gas pressure test ok - tagged meter location
|
MEC19-01966
| Rough-in | 5/21/2019 | 5/22/2019 | 5/22/2019 2:03:21 PM | P | PASS |
|
|
Call Jason @ ###-#### with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire - R/I ok
|
MEC19-02124
| Final | 5/21/2019 | 5/22/2019 | 5/22/2019 1:48:26 PM | P | NR |
|
|
Please call Chuck on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
|
MEC19-02033
| Rough-in | 5/21/2019 | 5/22/2019 | 5/22/2019 1:35:55 PM | P | FAIL |
|
|
pressure test Inspection requested via web by Lynn Johnston - 20lb gas pressure test fail -gas line penetration needs to be wrapped with 10 mill tape - condensate line for high wall unit needs finished in the crawl
|
MEC19-02033
| Pressure Test | 5/22/2019 | 5/22/2019 | 5/22/2019 1:34:55 PM | P | FAIL |
|
|
pressure test Inspection requested via web by Lynn Johnston - gas pressure gauge needs to be a 30lb gauge set at 20lb
|
MEC19-02131
| Final | 5/22/2019 | 5/22/2019 | 5/22/2019 1:32:22 PM | P | PASS |
|
|
Please call Dave at ###-#### or Dan at ###-#### with a 30 minute heads up arrival time for access. Thanks! Phone #: ###-#### Inspection requested via web by David or K Cole - air hander hp coil ok
|
MEC19-01910
| Final | 5/20/2019 | 5/22/2019 | 5/22/2019 1:11:15 PM | P | FAIL |
|
|
Steve Phone #: ###-#### - furnace only co ok - need to see a plumbing permit pulled for water heater for final of mech permit
|
MEC19-00986
| Rough-in | 5/21/2019 | 5/22/2019 | 5/22/2019 11:36:23 AM | A | PASS |
|
|
Scott with Idaho Home Improvement is calling in for framing inspection during AM as well. If needed contact information for Scott is ###-#### Phone #: ###-#### Inspection requested via web by Ashley Shoecraft - fireplace R/I ok
|
MEC19-02135
| Rough-in | 5/21/2019 | 5/22/2019 | 5/22/2019 11:09:20 AM | A | FAIL |
|
|
Inspection must be between 10AM-12:30PM to allow access to home. Please Call or Text Scott at ###-#### with questions or concerns. Thank you!! Phone #: ###-#### Inspection requested via web by Ashley Shoecraft - wood fireplace width framing is too small manufactures install states 49" and 3/4 clearances to side and framing is only 48"
|
MEC19-02024
| Final | 5/20/2019 | 5/22/2019 | 5/22/2019 10:28:51 AM | A | NH |
|
|
PLEASE CALL CUSTOMER BEFORE HEADING OUT. MORNING APPT. REQUESTED. Phone #: ###-#### Inspection requested via web by Trina DeBoard - no access to home left notice on front door
|
MEC19-01957
| Rough-in | 5/21/2019 | 5/22/2019 | 5/22/2019 10:12:22 AM | A | PASS |
|
|
PART Phone #: ###-#### Inspection requested via web by Oleg Chervak - BLD G pre rock R/I ok
|
MEC19-02028
| Final | 5/21/2019 | 5/22/2019 | 5/22/2019 9:39:09 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok
|
MEC19-02076
| Final | 5/21/2019 | 5/22/2019 | 5/22/2019 8:54:03 AM | A | PASS |
|
|
Inspection requested via web by Marisa Hone - air handler hp coil ok
|
MEC19-00739
| Final | 5/21/2019 | 5/22/2019 | 5/22/2019 8:35:11 AM | A | PASS |
|
|
Mechanical Gas Fireplace Final inspection Manual in drawer next to the fridge in kitchen Garage code 5674 or 9378 Phone #: ###-#### Inspection requested via web by Dan Otero - fireplace final ok
|
MIS19-00132
| MEC-Conference | 5/21/2019 | 5/22/2019 | 5/22/2019 8:11:48 AM | A | FAIL |
|
|
work being done without permit / Phone #: 208###-####
-need mechanical permit for underground gas line, unit heater and bathroom in shop.
|
MEC18-03185
| Mec-Aging Inspection | 5/22/2019 | 5/22/2019 | 5/22/2019 8:08:15 AM | | FAIL |
|
|
If correction has been made to the A/C breaker size schedule an inspection with the homeowners. Permit will expire at the next mechanical aging inspection and will have to be re issued once expired
|
MEC18-04987
| Mec-Aging Inspection | 5/22/2019 | 5/22/2019 | 5/22/2019 8:05:38 AM | | DONE |
|
|
WIP
|
MEC19-02066
| Pressure Test | 5/21/2019 | 5/22/2019 | 5/21/2019 4:14:21 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks
|