MEC20-01931
| Final | 5/18/2020 | 5/22/2020 | 5/22/2020 3:18:12 PM | P | PASS |
|
|
INSTALLER DAKOTA ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC20-00512
| Final | 5/22/2020 | 5/22/2020 | 5/22/2020 2:46:16 PM | P | PASS |
|
|
Mechanical Gas Fireplace Final Inspection. Manual is on shelf next to furnace. Garage Code: 5354 Phone #: ###-#### Inspection requested via web by Dan Otero
|
MEC20-01967
| Final | 5/20/2020 | 5/22/2020 | 5/22/2020 2:26:27 PM | P | FAIL |
|
|
Please contact Pete the homeowner with and ETA. Thank You! Phone #: ###-#### Inspection requested via web by Kelly Martin - need to witness flue pressure test
|
MEC20-01985
| DOC - Permit Finaled | 5/22/2020 | 5/22/2020 | 5/22/2020 2:07:27 PM | P | PASS |
|
|
|
MEC20-02012
| Rough-in | 5/22/2020 | 5/22/2020 | 5/22/2020 2:05:48 PM | P | PASS |
|
|
please come late after noon Phone #: ###-#### Inspection requested via web by Oleg Chervak
|
MEC20-02012
| Pressure Test | 5/22/2020 | 5/22/2020 | 5/22/2020 2:05:38 PM | P | FAIL |
|
|
please come late after noon Phone #: ###-#### Inspection requested via web by Oleg Chervak -20lb test passed - gaspipe needs 10 mill tape where it exits building
|
MEC19-04768
| Rough-in | 5/22/2020 | 5/22/2020 | 5/22/2020 1:52:31 PM | P | PASS |
|
|
GC is request for inspection on one fire/smoke damper in hallway by elevator for lid cover. Nick will be on site ###-####. Valor Point 42359 Phone #: ###-#### Inspection requested via web by adrian manzo - 1st fllor firesmoke damper angle above exit door bye elevator
|
MEC20-01622
| Rough-in | 5/22/2020 | 5/22/2020 | 5/22/2020 1:19:55 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Amanda Casper - dryervent needs nailplates - bvent firestops need firecaulk -return plenum in basement needs all wood panned off with metal -water heater needs combustion air
|
MEC20-01622
| Pressure Test | 5/22/2020 | 5/22/2020 | 5/22/2020 1:18:06 PM | P | PASS |
|
|
High side gage at meter, low side gage is range - Phone #: ###-#### Inspection requested via web by Amanda Casper -60lb,5lbx2
|
MEC20-01898
| Rough-in | 5/22/2020 | 5/22/2020 | 5/22/2020 12:31:59 PM | P | CANC |
|
|
if something is amiss, can you call me?
Nat ###-#### Phone #: ###-#### Inspection requested via web by Nat Golden
|
MEC20-01898
| Rough-in | 5/22/2020 | 5/22/2020 | 5/22/2020 11:47:28 AM | P | PASS |
|
|
if something is amiss, can you call me?
Nat ###-#### Phone #: ###-#### Inspection requested via web by Nat Golden - all bedrooms need transfers on final - new dryervent okay
|
MEC20-01985
| Pressure Test | 5/21/2020 | 5/22/2020 | 5/22/2020 11:32:58 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by yuriy kryachun - pressure test 20lb okay,,,, - gas piping needs yellow 18ga tracer wire - be sure minimum burial depth of 8" to finish grade is achieved
|
MEC20-02003
| Rough-in | 5/21/2020 | 5/22/2020 | 5/22/2020 10:51:56 AM | A | PASS |
|
|
SAM ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
|
MEC20-01969
| Final | 5/21/2020 | 5/22/2020 | 5/22/2020 10:19:08 AM | A | PASS |
|
|
*screened* Benny Phone #: ###-####
|
MEC20-01187
| Final | 5/21/2020 | 5/22/2020 | 5/22/2020 9:34:26 AM | A | PASS |
|
|
CLINT ###-#### CODE: 1957 Phone #: ###-#### Inspection requested via web by Mike Almanza
|
MEC20-01677
| Rough-in | 5/22/2020 | 5/22/2020 | 5/22/2020 9:04:25 AM | P | FAIL |
|
|
please check gas connection tobe sure you will be able to still connect after drywall MBR
|
MEC20-01870
| Pressure Test | 5/21/2020 | 5/22/2020 | 5/22/2020 9:02:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Arielle Hendricks -60lb okay -5lbx2 - need sleeve on gas piping MBR fireplace
|
MEC20-01870
| Rough-in | 5/21/2020 | 5/22/2020 | 5/22/2020 9:01:13 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Arielle Hendricks - need one more nailplate on dryer vent - need sleeve on gas piping MBR fireplace
|
MEC19-03489
| Mec-Aging Inspection | 5/22/2020 | 5/22/2020 | 5/22/2020 8:02:55 AM | | CANC |
|
|
|
MEC19-03489
| DOC - Permit Expired | 5/22/2020 | 5/22/2020 | 5/22/2020 8:02:50 AM | P | PASS |
|
|
|
MEC19-04884
| Final | 5/21/2020 | 5/22/2020 | 5/21/2020 6:38:03 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Ed Ables Inspection cancelled from web by: Ed Ables
|