Inspections for the day of: Monday, May 23, 2005.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01765 Final5/23/20055/23/20055/23/2005 4:24:24 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Dana Moyer ok to final
ELE05-01814 Electrical Rough-In5/23/20055/23/20055/23/2005 3:33:02 PMPPART
underground inspection///jeremy ###-#### u/g for outside except main entry into property ok to cover
ELE05-01799 Temporary Service5/23/20055/23/20055/23/2005 2:53:24 PMPFAIL
###-#### - dan called tried to leave message, couldn't get through, 250.53(G) the upper end of the electrode shall be flush with or below ground unless protected, 406.5 receptacle covers shall completely cover the opening and seat against the mount
ELE05-01800 Electrical Rough-In5/23/20055/23/20055/23/2005 2:36:09 PMPFAIL
###-#### - dan - Note: cover 314.17(A) openings shall be closed where conductors enter(can lights), 314.20, in walls of combustible material, boxes shall be flush with finished surface(so garage lite), 250.148(C) metal boxes shall be grounded, BC
ELE05-01800 Permanent Service5/23/20055/23/20055/23/2005 2:30:38 PMPFAIL
###-#### - dan 312.5 conductors entering enclosures shall be protected from abrasion (gec into panel)
ELE05-01630 Electrical Rough-In5/23/20055/23/20055/23/2005 1:32:59 PMPPASS
Under slab raceways; Phone #: ###-#### Internet Inspection Request from: Nikki Day under slab conduit for south (gym) ok to cover
ELE05-01794 Temporary Service5/20/20055/23/20055/23/2005 9:49:15 AMAPASS
ron ###-#### t/s u/g n ok
ELE05-01808 Rough-In Permanent Service5/23/20055/23/20055/23/2005 9:48:32 AMPPASS
clyde ###-#### called contr about mbr recpt, he said they build pony wall after set tub, the mount rcpt. ric ok. p/s u/g n ok
ELE05-01790 Temporary Service5/20/20055/23/20055/23/2005 9:03:55 AMAPASS
ron ###-#### called left message about labels. t/s u/g n ok
ELE05-01793 Temporary Service5/20/20055/23/20055/23/2005 8:48:37 AMAPASS
ron ###-#### called left message about labels. t/s u/g n ok
ELE05-01792 Temporary Service5/20/20055/23/20055/23/2005 8:46:38 AMAPASS
ron ###-#### called ,left message about labels t/s u/g n ok
ELE05-01791 Temporary Service5/20/20055/23/20055/23/2005 8:28:16 AMAPASS
ron ###-#### called, left message about labels. t/s u/g n ok
ELE05-01226 Electrical Rough-In5/21/20055/23/20055/23/2005 8:17:38 AMAPASS
Scheduled by a contractor via Hello! on 5/21/2005 at 9:51:10 AM. Contact: ###-####. potting only ok 2 fixtures