Inspections for the day of: Tuesday, May 23, 2006.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-00482 Rough-In Permanent Service5/23/20065/23/20065/23/2006 4:27:51 PMPNH
tom; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie called contr, door locked, needs to call later
ELE05-02630 Permanent Service5/22/20065/23/20065/23/2006 3:58:46 PMPCANC
Phone #: ###-#### Internet Inspection Request from: Celinda Winters bld says no electrical planned for bldg, talked to contr, told to get permits in order for an inspection
ELE06-01336 Final5/23/20065/23/20065/23/2006 3:27:52 PMPPASS
###-#### - doug ok to final
ELE06-01409 Final5/23/20065/23/20065/23/2006 2:29:23 PMPFAIL
ethan - call prior to insp; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie called contr, left corr notice, nec 210.12(B) all 120v 15 and 20A branch circuits supplying outlets in dwelling unit bedrooms shall be protected by a listed arc-fault circuit interrupter, 314.20 in walls of combustible material box shall be flush with finished surface, 314.21 drywall shall be finished so there are no gaps greater than 1/8", 406.5 faceplates shall be installed to completely cover opening and seat against surface, 406.4(D) recpts shall be flush with or project from faceplates
ELE06-01840 Final5/23/20065/23/20065/23/2006 1:52:24 PMPPASS
lona; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s o/h rec ok
ELE05-01308 Final5/23/20065/23/20065/23/2006 1:22:44 PMPPASS
stonemill deli suite 104-tom; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok to final, signed occ card
ELE06-01773 Final5/22/20065/23/20065/23/2006 11:37:19 AMAPASS
need final inspection on new 200 amp service. please call Page Sausman to meet @ ###-####. thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ok to final
ELE06-01773 Permanent Service5/23/20065/23/20065/23/2006 11:36:53 AMAPASS
need final inspection on new 200 amp service. please call Page Sausman to meet @ ###-####. thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH p/s u/g rec ok
ELE05-04387 Electrical Rough-In5/22/20065/23/20065/23/2006 10:26:39 AMAPASS
ceiling insp- nathan; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to cover ceiling
ELE06-01835 Temporary Service5/22/20065/23/20065/23/2006 10:09:23 AMAFAIL
joe-- ###-####-- for a temp pole called contr, left corr notice, nec 110.12(A) unused openings shall be closed, 110.12(C) there shall be no broken parts, 230.26 in no case shall service conductors be less than 10' above finished grade, 110.14(A) connections of conductors to terminals shall ensure thoroughly good connections, 110.26(A) work space shall be provided about equipment
ELE05-04271 Final5/22/20065/23/20065/23/2006 9:50:48 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Eric Shaner ok to final
ELE06-00833 Electrical Rough-In5/22/20065/23/20065/23/2006 9:02:46 AMAPASS
gill- call 1/2 hr before insp ; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to cover ceiling only
ELE06-01807 Electrical Rough-In5/22/20065/23/20065/23/2006 8:12:56 AMACANC
rough-in inspection as early as possible on 05/23 a.m. Contact is Greg ###-####. Thanks.; Phone #: ###-#### Internet Inspection Request from: Steve Syltie request cancel due to saw cutting problems, called contr to verify. Will recall ltr.