Inspections for the day of: Friday, May 23, 2014.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-00227 ELE-Aging Inspection5/23/20145/23/20145/29/2014 4:01:39 PM DONE
Still under construction
ELE12-02376 ELE-Aging Inspection5/23/20145/23/20145/29/2014 3:50:40 PM DONE
Spoke to contractor will check
ELE12-02290 Final5/22/20145/23/20145/23/2014 3:37:31 PMAPASS
Contact person Jim Snodgrass Phone #: ###-#### >> Inspection requested via web by Todd Sellman Final ok
ELE14-01316 Conference5/22/20145/23/20145/23/2014 3:27:38 PMAFAIL
need conference on what is going to be required to repair wiring in kitchen due to fire. Please call Andy @ ###-#### to set time to meet. Phone #: ###-#### >> Inspection requested via web by Andy Rose Due to small kitchen fire ceiling and some drywall has been removed in kitchen. BCC 4-05-32- Code violation not to be retained. When altering pre-existing wiring the electrical witing in close proximity shall be in accordance with present code.
1- NEC 210.8 All kitchen counter top receptical outlets shall have GFCI protection.
2- NEC 210.11(C)(1)- Kitchen counter top receptical outlets shall be fed by a minimum of 2 20 amp small appliance circuits that shall have no other outlets.
BCC 4-05-31(C)- Unfused conductors shall not enter a structure. Main fused disconnecting means shall be installed outside as per NEC 230.70 and 230.71.
NEC 110.26- Minimum work space shall be 30" wide and 36" deep at panel location.
ELE13-03546 Electrical Rough-In5/23/20145/23/20145/23/2014 3:10:47 PMPFAIL
partial basement ceiling - Mike Phone #: ###-#### 300.11 Hard lid support system shall not support light fixtures and boxes unless system is rated for support of additional fixtures.
ELE14-01329 Electrical Rough-In5/23/20145/23/20145/23/2014 2:49:32 PMPPASS
Rocky Phone #: ###-#### Walls and hard lid rough in ok cover
ELE14-01126 Electrical Rough-In5/23/20145/23/20145/23/2014 1:35:14 PMPPASS
Rocky Phone #: ###-#### Walls and hard lid rough in ok cover
ELE14-01330 Electrical Rough-In5/23/20145/23/20145/23/2014 12:58:44 PMPPASS
Warren-around 1 if possible please Phone #: ###-#### Wall rough in ok cover
ELE14-01219 Final5/23/20145/23/20145/23/2014 12:13:50 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack Final ok
ELE14-00987 Final5/23/20145/23/20145/23/2014 11:30:16 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Terry Scott Final ok
ELE14-01310 Permanent Service5/22/20145/23/20145/23/2014 11:21:19 AMAFAIL
There hasn''t been a meter at this location for over a year, Idaho Power is requiring an inspection of the service before powering. Phone #: ###-#### >> Inspection requested via web by Stephen Kren
110.26- Minimum work space of 30" wide and 36" deep shall be provided for panel location.
230.71- Maximum of 6 disconnects for service disconnecting means
ELE14-01188 Electrical Rough-In5/23/20145/23/20145/23/2014 9:50:56 AMPPASS
Kelly Phone #: ###-#### Basement and kitchen rewired main level existing. Rough in ok cover
ELE14-01319 Electrical Rough-In5/22/20145/23/20145/23/2014 9:35:32 AMAPASS
Please call Lynn Proctor at ###-#### on your way to the site. Phone #: ###-#### >> Inspection requested via web by Lynn Proctor Interior surface conduits and recepticals rough in ok
ELE14-01319 Permanent Service5/22/20145/23/20145/23/2014 9:34:41 AMAPASS
Please call Lynn Proctor at ###-#### on your way to the site.. Phone #: ###-#### >> Inspection requested via web by Lynn Proctor p/s u/g n ok
ELE14-00537 Final5/22/20145/23/20145/23/2014 8:53:43 AMAPASS
It will be unlocked. Please let me know if there are any problems. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan Final ok