Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
GCM14-00130 GCM-Final5/23/20145/23/20145/23/2014 4:47:53 PMPPASS
###-#### please schedule for as late in the afternoon as possible..furn..w/h..a/c..ok for final
GCM14-00130 GCM-Pressure Test5/23/20145/23/20145/23/2014 4:47:00 PMPPASS
###-#### please schedule for as late in the afternoon as possible..flue test ok
GCM14-00128 GCM-Rough-in5/22/20145/23/20145/23/2014 4:24:02 PMPPART
all rooms in east wing ok for cover..ok to insulate ducts in hallways
MEC14-01034 Conference5/23/20145/23/20145/23/2014 3:40:46 PMPPEND
I called Troy Blanton with Black Eagle and told him it's up to the engineer to spec out the dampers..My job is to make sure they are installed per the manuf.
MEC14-01988 Rough-in5/23/20145/23/20145/23/2014 3:31:03 PMPPASS
Phone #: ###-#### >> Inspection requested via web by April Thomas
MEC14-01988 Pressure Test5/23/20145/23/20145/23/2014 3:30:12 PMPPASS
Phone #: ###-#### >> Inspection requested via web by April Thomas..20lb ok
MEC14-01983 Final5/23/20145/23/20145/23/2014 2:15:39 PMPPASS
tim ###-####..r/i and final ok
MEC14-01987 Rough-in5/23/20145/23/20145/23/2014 2:14:46 PMPPASS
jeff ###-####..flue ok through chase..bath exhaust and supply runs ok
MEC14-01987 Final5/23/20145/23/20145/23/2014 2:13:10 PMPNR
Contact Jeff for access: ###-#### Phone #: ###-#### >> Inspection requested via web by Frank Marturello
MEC14-01971 Final5/22/20145/23/20145/23/2014 2:11:46 PMPPASS
Phone #: ###-#### >> Inspection requested via web by April Thomas
MEC14-01858 Rough-in5/22/20145/23/20145/23/2014 11:30:08 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Joe Bertwell
MEC14-01983 Rough-in5/22/20145/23/20145/23/2014 11:01:45 AMAPASS
Need to call before about 1/2 prior Thanks Rene Phone #: ###-#### >> Inspection requested via web by Rene Neumeyer
MEC14-01983 Pressure Test5/22/20145/23/20145/23/2014 11:01:16 AMAPASS
Need to call before about 1/2 prior Thanks Rene Phone #: ###-#### >> Inspection requested via web by Rene Neumeyer..20lb gas ok
GCM14-00104 GCM-Final5/22/20145/23/20145/23/2014 10:35:34 AMAPASS
Don ###-####
GCM14-00072 GCM-Final5/22/20145/23/20145/23/2014 9:53:41 AMAFAIL
no manual j on site..no air balance..wrong coil installed
GCM14-00119 GCM-Final5/22/20145/23/20145/23/2014 9:16:05 AMAPASS
Please call ahead of time
MEC14-01946 Final5/22/20145/23/20145/23/2014 8:46:04 AMAPASS
miquel ###-####