Inspections for the day of: Friday, May 23, 2014.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC13-01210 Site Preparation5/23/20145/23/20145/23/2014 2:32:01 PMPPASS
Small addition to existing pet clinic. Project is on the west side of building facing parking lot.

BMPs include:
permit posted
parking lot storm drain protection
preserve existing vegetation
ESC14-00168 General Inspection5/23/20145/23/20145/23/2014 1:19:17 PMPPART
Trackout from empty parcel where stockpiling needs to be swept.

If the lot is to be used as a stockpile/staging area a general ESC permit should be obtained and the lot returned to pre-existing conditions.
ESC14-00106 Random Inspection5/23/20145/23/20145/23/2014 11:40:16 AMAPASS
No trackout or sediment leaving site. Permit posted. No corrections at this time.
ESC14-00297 General Inspection5/23/20145/23/20145/23/2014 11:28:53 AM PASS
Keeping materials in a trailer on driveway. Permit posted. No sediment leaving site.
ESC13-00995 Aging Inspection5/23/20145/23/20145/23/2014 11:21:04 AM PASS
Finaled.
ESC13-00995 DOC - Permit Finaled5/23/20145/23/20145/23/2014 11:18:02 AMPPASS
Final landscaping touches being applied. Construction and stabilization of disturbed area complete. BLD permit finaled.
ESC13-00844 DOC - Permit Finaled5/23/20145/23/20145/23/2014 11:04:18 AMPPASS
Lightning rod for new air tower is complete and surrounding area stabilized. ESC conditions satisfied.
ESC14-00263 General Inspection5/23/20145/23/20145/23/2014 10:50:16 AM PASS
No violations observed.
ESC13-00940 General Inspection5/23/20145/23/20145/23/2014 10:36:08 AM PASS
Finaled.
ESC13-00940 DOC - Permit Finaled5/23/20145/23/20145/23/2014 10:35:39 AMPPASS
Grass has sprouted in over 70% of disturbed area. No further construction activity. Grass grew slow and needs more irrigation, but ESC conditions satisfied.
ESC14-00200 General Inspection5/22/20145/23/20145/23/2014 10:27:36 AMAPASS
Involta Data Center site has been graded and compacted. Crews onsite installing underground utilities.

Perimeter silt fence is good condition and wide buffer seperates the creek to the north. Construction entrance is large grade rock and effective, some minor trackout to street can be swept at end of day. Permit posted, SWPPP on site.

No corrections at this time.
ESC13-00924 General Inspection5/23/20145/23/20145/23/2014 10:07:05 AM PASS
Pinetree Village in good condition. No trackout issues. Centralized material storage area has been established, reducing the amount of disturbance. Townhomes in new phase are in progres. DI's have filter bag protection. No corrections at this time.
ESC13-00655 Random Inspection5/23/20145/23/20145/23/2014 9:42:14 AMPPASS
Aberdeen Square central access alleys and stormwater infrastructure has been installed. Work on individual units along Raymond. Sidewalk is dusty, but street is clean. Drop inlets have protection. Approved.
ESC13-00658 DOC - Permit Finaled5/23/20145/23/20145/23/2014 9:40:06 AMPPASS
4-plex complete, landscaped, and occupied. ESC conditions satisfied. Aberdeen Square sub currently in compliance with new units underway.
ESC13-00989 Aging Inspection5/23/20145/23/20145/23/2014 9:27:26 AM PASS
Finaled.
ESC13-00989 DOC - Permit Finaled5/23/20145/23/20145/23/2014 9:27:14 AMPPASS
Complete, landscaped, ESC conditions satisfied. All permits finaled.
ESC14-00287 General Inspection5/23/20145/23/20145/23/2014 8:50:30 AM PASS
Interior renovation. Materials and equipment confined to staging area. Approved.