Inspections for the day of: Tuesday, May 23, 2017.
Number of inspections: 7
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-03931 Electrical Rough-In5/23/20175/23/20175/23/2017 2:17:39 PMPPASS
units 608-622 corridors 537A, 537B, 537C Phone #: ###-#### Inspection requested via web by Cathy Duchek
Book located in general contractors job trailer to sign off on inspections.
601, 602, 604 thru 608 and 621, 622 and firelids for corridors noted rough in ok cover
ELE13-01291 Electrical Rough-In5/22/20175/23/20175/23/2017 2:02:12 PMPPASS
Please inspect the next site amphitheater wall rough in raceways and boxes. Phone #: ###-#### Inspection requested via web by Tom Betty
Level 7 pour rough in ok cover
ELE17-00624 Final5/22/20175/23/20175/23/2017 12:54:31 PMPPASS
Jason is the contact his cell no is ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates
Final ok
ELE17-01236 Final5/22/20175/23/20175/23/2017 11:07:54 AMAPASS
Dan Phone #: ###-#### Inspection requested via web by Dan
Final ok
ELE17-01555 Rough-In Permanent Service5/22/20175/23/20175/23/2017 10:42:14 AMAPASS
Need inspection on overhead service and roughin for out building in West back yard. Enter through gate on left side of the house. Phone #: ###-#### Inspection requested via web by Alan Lusk
Shed rough in ok cover p/s o/h n ok
ELE17-01552 Rough-In Permanent Service5/22/20175/23/20175/23/2017 9:54:06 AMAPASS
access code 5343 Phone #: ###-#### Inspection requested via web by David Nelson
Check permit fee for future work. Rough in of 2 gang box for GFCI below panel ok. All other circuits have been disconnected.
p/s u/g rec ok
ELE17-01529 Rough-In Permanent Service5/22/20175/23/20175/23/2017 9:06:10 AMAFAIL
Phone #: ###-#### Inspection requested via web by Bob Glenn
300.4- Where MN cable is run thru bored holes that do not maintain 1 1/4" from framing surface shall be protected from physical damage by nail plates. 45 degree corners.
300.15- Splice point to concrete encased electrode shall be accessible. Provide mudring.
725.136- Class 2 wiring shall not occupy same box unless seperated by a barrier. Kitchen 4 gang.