Inspections for the day of: Thursday, May 23, 2019.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-01942 Final5/21/20195/23/20195/23/2019 2:46:07 PMPPASS
Sue ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co ok
MEC19-02092 Final5/20/20195/23/20195/23/2019 2:25:40 PMPPASS
THIS IS APARTMENT #3 ON 2ND STORY
INSTALLER BRANDAN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
MEC19-02154 Rough-in5/23/20195/23/20195/23/2019 1:50:04 PMPCANC
Phone #: ###-#### Inspection requested via web by Matthew BLANKENSHIP- wrong address- need to get permit issued for right unit
MEC19-02148 Final5/22/20195/23/20195/23/2019 1:11:10 PMPPASS
Please call Florence prior to arriving. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace a/c coil co ok
MEC19-02042 Final5/23/20195/23/20195/23/2019 11:45:03 AMAPASS
furnace a/c coil co ok- 5lb flue test pass
MEC19-01972 Final5/23/20195/23/20195/23/2019 11:39:11 AMAPASS
final ok- card signed
MEC19-01615 Final5/16/20195/23/20195/23/2019 11:33:32 AMAPASS
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 11:30. Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok- 5lb flue test pass
MEC19-01857 Final5/20/20195/23/20195/23/2019 11:05:40 AMAFAIL
Please call Brian Plew prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace connection to flue missing manufactures screws- b vent needs 1" clearance to armor flex- need to replace chimney liner and install approved chimney connector in chimney and seal- b vent needs 1/4" rise per foot from furnace to chimney connection
MEC19-02082 Rough-in5/22/20195/23/20195/23/2019 10:09:26 AMAFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart
1- gas test failed at 13psi
2- need to insulate bare metal on supply plenums where round ties into square duct and all wye branch fittings in attic where bare metal showing to R-8
3- supply main to master bedroom needs 3 inch clearance to fireplace flue in attic
4- need ladder provided by contractor to access furnace/coil in attic
5- need to insulate filter box for outside air in attic where ties onto return plenum bare meatal showing
6- master bath exhaust in toilet room needs metal to plactic connection sealed at fan location

left correction notice front entry window
MEC19-02082 Pressure Test5/22/20195/23/20195/23/2019 10:01:50 AMAFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart- gas test failed gauge at 13psi
MEC19-02119 Final5/22/20195/23/20195/23/2019 9:46:02 AMAPASS
please call 30 min before arrival I will meet you there . ###-#### Phone #: ###-#### Inspection requested via web by Don Dowers- furnace a/c coil ducting co ok
MEC19-02119 Pressure Test5/23/20195/23/20195/23/2019 9:45:41 AMAPASS
please call 30 min before arrival I will meet you there . ###-#### Phone #: ###-#### Inspection requested via web by Don Dowers- 20lb gas pass
PLM19-02101 Water Heater Final5/23/20195/23/20195/23/2019 9:45:18 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Bennett- Water heater final ok- co installed
MEC18-05701 Final5/23/20195/23/20195/23/2019 9:16:35 AMAPASS
electrical permit has been issued
MEC19-02102 Final5/23/20195/23/20195/23/2019 9:15:14 AMAPASS
electrical permit has been issued
MEC19-01913 Final5/16/20195/23/20195/23/2019 9:00:18 AMAFAIL
Please inspect before 11 AM. Rachel Aivles ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok- need to insulate return air plenum in garage to R-6
MEC18-02208 Mec-Aging Inspection5/23/20195/23/20195/23/2019 8:04:22 AM CANC
MEC18-02208 DOC - Permit Expired5/23/20195/23/20195/23/2019 8:04:10 AMAPASS
no activity
MEC19-00677 Final5/22/20195/23/20195/22/2019 3:07:28 PMACANC
4141 Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves