Inspections for the day of: Wednesday, May 24, 2006.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-01131 Electrical Rough-In5/24/20065/24/20065/24/2006 4:08:38 PMPPASS
bernice; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
R/I Ok
P/S U/G N Ok
ELE06-01863 Conference5/24/20065/24/20065/24/2006 3:33:58 PMPPART
Seth; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
talked about concrete encased electrode and service.
electrode ok for concrete
ELE06-01833 Final5/24/20065/24/20065/24/2006 2:47:18 PMPFAIL
need inspection on wiring to garage and in garage. Please call Bob @ ###-#### or ###-#### to set time to meet so he can let you in he needs 30 minutes to get there. Any other questions call Andy @ ###-#### Internet Inspection Request from: Andy Rose
feed 3 way for outside light hot from the garage.
isolate neutral and drive 2nd ground rod.
ELE06-01891 Final5/24/20065/24/20065/24/2006 1:54:56 PMPFAIL
jerry - call prior to insp for access ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
no recep within 25 ft of condenser.
ELE06-01719 Final5/24/20065/24/20065/24/2006 1:01:14 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Dana Moyer
ELE06-01667 Rough-In Permanent Service5/24/20065/24/20065/24/2006 11:51:54 AMAPASS
garage and new service; Phone #: ###-#### Internet Inspection Request from: Jim Williams
will schedual conf on service
R/I Ok
ELE06-01804 Electrical Rough-In5/23/20065/24/20065/24/2006 11:20:32 AMAPART
the wrong area was inspected yesterday. This permit is for the 2nd floor. Yesterdays inspection was in the area for our permit ELE06-01705. Please call Loren to clarify ###-####.; Phone #: ###-#### Internet Inspection Request from: Steve Syltie
walls ok
ELE06-00361 Final5/23/20065/24/20065/24/2006 11:10:31 AMAPASS
mark; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
no card
ELE05-01295 Final5/23/20065/24/20065/24/2006 10:23:00 AMAPASS
mark; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
final ok no card
ELE06-01859 Conference5/23/20065/24/20065/24/2006 10:18:55 AMADONE
Dennis, please call 1st; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
no more services to this bldg
ELE06-01853 Rough-In Permanent Service5/23/20065/24/20065/24/2006 9:26:09 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Daryl DeGrange
R/I Ok
P/S O/H N Ok
ELE06-01862 Final5/23/20065/24/20065/24/2006 9:01:04 AMANR
clyde- call prior to insp; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
correction on service
ELE06-01862 Permanent Service5/23/20065/24/20065/24/2006 9:00:31 AMAFAIL
clyde- call prior to insp; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
run neutrals to panel
dryer circuit shall be #10 wire and 30 amp.
dryer and range to be 4 wire.
neutral to range shall be white.
ELE06-01218 Rough-In Permanent Service5/23/20065/24/20065/24/2006 12:00:00 AMAPASS
this inspection was done under ele06-01853. That # is a duplicate and will be voided.rad