Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01881 Rough-In Permanent Service5/24/20075/24/20075/24/2007 3:53:27 PMPNR
rick; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, no stairs to get in, no boxes on garage lights, no rear recpt, told to provide access to do inspection
ELE07-01465 Final5/24/20075/24/20075/24/2007 3:37:20 PMPPASS
Final Inspection. Please call Steve Ruter to get access Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson ok to final
ELE07-01880 Rough-In Permanent Service5/24/20075/24/20075/24/2007 3:07:49 PMPPASS
lee Note: corner of targee & Hilton; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ric ok, ok to cover u/g, p/s,exst pedestal , rec, ok
ELE06-00311 Conference5/24/20075/24/20075/24/2007 2:04:01 PMPDONE
craig ; Phone #: ###-#### - please call 1/2 hr prior to inspection Internet Inspection Request from: Patricia Smith talked about new service for house and subfeeding shop and garage, grounding o/h clearances
ELE07-01718 Electrical Rough-In5/24/20075/24/20075/24/2007 1:18:54 PMPFAIL
butch ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called contr, left corr notice, nec 300.4(A)&(D) edge of bored holes and raceway shall be 1 1/4" from edge of framiong members, 314.20 in walls of combustible material, boxes shall be flush with or project from finished surface, talked about new service, they are going to mount 400a on pole, then have 2 subpanels, 1 new, 1 exst, told to isolate neut and ground in subpanels
ELE07-01822 Electrical Rough-In5/24/20075/24/20075/24/2007 12:34:20 PMPFAIL
wall inspection//Trent ###-#### no inspection done, elect permit not tied to bld permit, put on stop work, double fee
ELE07-00200 Final5/24/20075/24/20075/24/2007 11:21:19 AMPCANC
Reinspection Phone #: ###-#### Internet Inspection Request from: Ryan Christensen Inspection cancelled from web by: Ryan Christensen
ELE07-00198 Final5/24/20075/24/20075/24/2007 11:21:14 AMPCANC
Reinspection Phone #: ###-#### Internet Inspection Request from: Ryan Christensen Inspection cancelled from web by: Ryan Christensen
ELE07-00197 Final5/24/20075/24/20075/24/2007 11:21:06 AMPCANC
Reinspection Phone #: ###-#### Internet Inspection Request from: Ryan Christensen Inspection cancelled from web by: Ryan Christensen
ELE07-01758 Electrical Rough-In5/23/20075/24/20075/24/2007 10:53:10 AMAPASS
ug conduit; added ug j-box Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack correction made, ok to cover u/g, j-box will be in pavers west of pool towards pool equip
ELE06-03165 Final5/23/20075/24/20075/24/2007 10:10:06 AMAPASS
Gary range and Dryer have been wired 4 wire; Phone #: ###-#### Internet Inspection Request from: Darla Downs ok to final
ELE07-01875 Final5/23/20075/24/20075/24/2007 9:34:50 AMAFAIL
israel - or luis at kendall ele. at ###-####; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called left message, left correction notice, BCC no violations shall be retained, nec 210.8(B)(2) commercial kitchens with permanent cooking facilities shall have all 125v 15 and 20a recpts gfci protected, 408.4 circuit directory shall be clear, concise, and direct
ELE07-00200 Final5/23/20075/24/20075/24/2007 8:55:00 AMANR
Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called, they wanted for pm, left corr notice, BCC all fixtures shall be mounted, switches installed,panel schedule done, polarity checked, no inspection done on this unit, fee due
ELE07-00198 Final5/23/20075/24/20075/24/2007 8:51:33 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called, left corr notice, nec 352.30(A) rnc shall be strapped within 3' of termination, 422.31(B) shall provide dishwasher lock-out, 210.52(B)(1) dishwasher shall not be on small appliance branch ckt, BCC all switch plates shall be installed, mount button switch, provide globe guard kitchen closet, address shall be posted
ELE07-00197 Final5/23/20075/24/20075/24/2007 8:21:44 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called left corr notice, nec 210.52(B)(1) dishwasher shall not be on small appliance branch ckt, 352.30(A) rnc shall be strapped within 3' of termination, 410.4(D) luminaire shall be listed for wet or damp location within 3' of shower space, 422.31(B) shall provide lock-out for dishwasher, BCC all boxes shall be closed and covers installed, address shall be posted