ELE10-01088
| Final | 5/24/2010 | 5/24/2010 | 5/25/2010 10:44:33 AM | P | PASS |
|
|
Bill 794 8435
|
ELE10-01036
| Rough-In Permanent Service | 5/24/2010 | 5/24/2010 | 5/24/2010 3:39:19 PM | P | CANC |
|
|
Inspection requested from web by: Tracy Robertson Phone #: ###-####
|
ELE10-01036
| Electrical Rough-In | 5/24/2010 | 5/24/2010 | 5/24/2010 3:39:10 PM | P | FAIL |
|
|
Inspection requested from web by: Tracy Robertson Phone #: ###-####. NEC 800.133 B Low voltage cable and phone need to be min. 2 inches from high voltage cables.
|
ELE10-01036
| Permanent Service | 5/24/2010 | 5/24/2010 | 5/24/2010 3:30:15 PM | P | PASS |
|
|
Inspection requested from web by: Tracy Robertson Phone #: ###-####. P/S U/G Connect ok.
|
ELE10-01039
| Rough-In Permanent Service | 5/24/2010 | 5/24/2010 | 5/24/2010 3:28:57 PM | P | PASS |
|
|
Inspection requested from web by: Tracy Robertson Phone #: ###-####
|
ELE10-00763
| Final | 5/24/2010 | 5/24/2010 | 5/24/2010 3:28:36 PM | P | PASS |
|
|
Inspection requested from web by: Tracy Robertson Phone #: ###-####
|
ELE10-00768
| Final | 5/24/2010 | 5/24/2010 | 5/24/2010 3:28:16 PM | P | FAIL |
|
|
Inspection requested from web by: Tracy Robertson Phone #: ###-####. Bathroom gfci not working in dojo
|
ELE10-01127
| Final | 5/21/2010 | 5/24/2010 | 5/24/2010 2:34:14 PM | A | PASS |
|
|
rex Phone #: ###-####
|
ELE10-00914
| Electrical Rough-In | 5/21/2010 | 5/24/2010 | 5/24/2010 2:33:59 PM | A | PASS |
|
|
Ceiling Inspection requested from web by: Clint Tate Phone #: ###-####
|
ELE10-01123
| Electrical Rough-In | 5/21/2010 | 5/24/2010 | 5/24/2010 1:27:03 PM | A | PASS |
|
|
Robert ###-####
|
ELE10-01123
| Final | 5/24/2010 | 5/24/2010 | 5/24/2010 1:26:47 PM | P | PASS |
|
|
Robert ###-####
|
MIS10-00070
| MIS-Aging Inspection | 5/24/2010 | 5/24/2010 | 5/24/2010 12:25:38 PM | P | PASS |
|
|
fyi came up on my aging. 301. Has been taken care of.
|
ELE10-01120
| Final | 5/20/2010 | 5/24/2010 | 5/24/2010 12:24:14 PM | A | PASS |
|
|
Inspection requested from web by: Matthew White Phone #: ###-####
|
ELE10-01122
| Final | 5/21/2010 | 5/24/2010 | 5/24/2010 12:13:40 PM | A | CANC |
|
|
We wired up 220 blower in attic Inspection requested from web by: Barbara Szurgot Phone #: ###-####. Going to reshedule for attic access.
|
MIS10-00146
| ELE-Conference | 5/21/2010 | 5/24/2010 | 5/24/2010 11:38:22 AM | A | FAIL |
|
|
Substandard renters complaint - clogged kitchen sink, started building a room on the side of the shed, tenant living in shed, turns furnace off when leaves house, no a/c, no fire extinguishers, electrical hazard issues // Kevin ###-####. Refer to mis10-00145
|
MIS10-00145
| ELE-Conference | 5/21/2010 | 5/24/2010 | 5/24/2010 11:37:45 AM | A | FAIL |
|
|
Go around back to gain access Substandard renters complaint - Sinks don't drain, only 1 outlet in rooms. Can easily be over loaded and cause a fire, no fire extinguishers, no locks on doors, doors do not open properly. Trip hazards all over the place. Refrigerater in front of breaker box. No handrail outside stairs. Someone living in the shed. Ladder to upstairs room (no stairs).//David ###-####. NEC 210.52 Outlet spacing in attic. Cord going through ceiling to attic.NEC 110.26 Refrigerator in front of sevice panel.
|
ELE10-00649
| DOC - Permit Finaled | 5/24/2010 | 5/24/2010 | 5/24/2010 10:18:11 AM | P | PASS |
|
|
|
ELE10-00958
| Final | 5/21/2010 | 5/24/2010 | 5/24/2010 10:04:32 AM | A | PASS |
|
|
|
ELE10-00958
| DOC - Permit Finaled | 5/24/2010 | 5/24/2010 | 5/24/2010 10:04:15 AM | P | PASS |
|
|
|