Inspections for the day of: Thursday, May 24, 2018.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-03551 ELE-Aging Inspection5/24/20185/24/20185/25/2018 9:00:11 AM FAIL
Daryl Degrange has made contact with contractor...still waiting on contractor
ELE13-02679 ELE-Aging Inspection5/24/20185/24/20185/25/2018 8:45:40 AM PASS
final scheduled...sign done by golden west sign..UL label verified
ELE14-00040 ELE-Aging Inspection5/24/20185/24/20185/25/2018 8:27:42 AM PASS
have left messages with no return calls...DOC expired
ELE14-00243 ELE-Aging Inspection5/24/20185/24/20185/25/2018 7:59:38 AM PASS
final scheduled to close permit
ELE05-03730 Final5/24/20185/24/20185/24/2018 3:24:47 PMPFAIL
Please call ahead for access - To close out previously completed work with re-opened permit - Kathy Phone #: ###-####...unable to close as per 3 other permits exist on address and have not been closed or inspections scheduled from Proctor Electric...electrical contractor has been notified and is going to schedule needed inspections and fix noted corrections
ELE18-00964 Electrical Rough-In5/24/20185/24/20185/24/2018 3:01:31 PMPPASS
after 2pm- Mitch Phone #: ###-####...ok to cover tile heat...squacker or continuity tester was removed found home owner standing on ladder on floor heat...discussed with her needed to stay off and with contractor that squaker needs put on to circuit...contractor taking full responsibility of floor heat
ELE18-00785 Final5/24/20185/24/20185/24/2018 2:30:04 PMPFAIL
Please call Shae on your way ###-####. After 1 pm would be best. If you have any questions please feel free to contact Luke ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan...1
1) panel circuits need to be properly labelled
2) bath outlet on GFCI breaker with GFCI outlet installed
3) furnace circuit shall not feed anything but furnace...dwn bath outlet
4) outlets need added within 6ft of fireplace either above cabinets or in wall
ELE18-00821 Final5/24/20185/24/20185/24/2018 12:51:57 PMPFAIL
code 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn...
1) no power in garage circuit
2) garage lights, kitchen lights no power
3) no power kitchen circuit
DID NOT checkout rest of house
ELE18-01740 Final5/24/20185/24/20185/24/2018 11:58:18 AMPCANC
Phone #: ###-#### Inspection requested via web by Robert Murray...scheduled wrong house
ELE18-01948 Final5/23/20185/24/20185/24/2018 11:39:35 AMPCANC
Jason is our contact Phone #: ###-#### Inspection requested via web by Kelly Felin...wrong inspection...temp service inspection scheduled
ELE18-01948 Temporary Service5/24/20185/24/20185/24/2018 11:39:01 AMPPASS
Jason is our contact Phone #: ###-#### Inspection requested via web by Kelly Felin...t/s u/g new ok
MIS18-00193 ELE-Conference5/23/20185/24/20185/24/2018 11:17:13 AMAFAIL
call Kandyce when on way out ###-#### // Substandard renters complaint: fuses in kitchen keep blowing, circuits possibly overloaded, bathroom tub and sink drain slow, smoke alarms not working, general life safety issues...
1) No GFCI protection in kitchen
2) multiple cooking appliances on kitchen circuit..overloading of circuit
3) no cover on panel or proper labelling...code violation
4) panel located in closet...code violation
5) no working smoke detectors in each bedroom
6) wiring done without proper permits...code violation

pictures have been taken and stored for future
ELE18-01926 Electrical Rough-In5/23/20185/24/20185/24/2018 10:01:22 AMAPASS
Chad VanOrden is contact at ###-####. thank you. Phone #: ###-#### Inspection requested via web by Debby Pierce...wall cover ok...contact contractor and discussed code 210.71-needs to add 1 outlet for wall requirement and floor outlet requirement
ELE18-01816 Electrical Rough-In5/23/20185/24/20185/24/2018 9:19:16 AMAPASS
Please call Ryan ###-#### when you head his way. Any electrical questions, you will want to call Fred at ###-####. Thank You!! Phone #: ###-#### Inspection requested via web by Clayton Morgan...dining rm cans, living rm cans, kitchen outlets and lighting, required outlets in open walls ok, others fished outlets in
ELE17-03829 Permanent Service5/23/20185/24/20185/24/2018 8:59:26 AMAPASS
Contact is Ryan Weiderich, Gate padlock code is 1950 if needed. Phone #: ###-#### Inspection requested via web by Scott Campbell...p/s u/g new ok meter is located south west corner of property close to freeway
ELE18-01950 Final5/24/20185/24/20185/24/2018 8:23:12 AMACANC
This Is All Ready To Go Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett...wrong inspection scheduled...temp service inspection scheduled
ELE18-01950 Temporary Service5/24/20185/24/20185/24/2018 8:22:30 AMAPASS
This Is All Ready To Go Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett...t/s o/h new ok
ELE18-01953 Permanent Service5/24/20185/24/20185/24/2018 8:19:04 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Jason Wicks Inspection cancelled from web by: Jason Wicks