ELE13-03551
| ELE-Aging Inspection | 5/24/2018 | 5/24/2018 | 5/25/2018 9:00:11 AM | | FAIL |
|
|
Daryl Degrange has made contact with contractor...still waiting on contractor
|
ELE13-02679
| ELE-Aging Inspection | 5/24/2018 | 5/24/2018 | 5/25/2018 8:45:40 AM | | PASS |
|
|
final scheduled...sign done by golden west sign..UL label verified
|
ELE14-00040
| ELE-Aging Inspection | 5/24/2018 | 5/24/2018 | 5/25/2018 8:27:42 AM | | PASS |
|
|
have left messages with no return calls...DOC expired
|
ELE14-00243
| ELE-Aging Inspection | 5/24/2018 | 5/24/2018 | 5/25/2018 7:59:38 AM | | PASS |
|
|
final scheduled to close permit
|
ELE05-03730
| Final | 5/24/2018 | 5/24/2018 | 5/24/2018 3:24:47 PM | P | FAIL |
|
|
Please call ahead for access - To close out previously completed work with re-opened permit - Kathy Phone #: ###-####...unable to close as per 3 other permits exist on address and have not been closed or inspections scheduled from Proctor Electric...electrical contractor has been notified and is going to schedule needed inspections and fix noted corrections
|
ELE18-00964
| Electrical Rough-In | 5/24/2018 | 5/24/2018 | 5/24/2018 3:01:31 PM | P | PASS |
|
|
after 2pm- Mitch Phone #: ###-####...ok to cover tile heat...squacker or continuity tester was removed found home owner standing on ladder on floor heat...discussed with her needed to stay off and with contractor that squaker needs put on to circuit...contractor taking full responsibility of floor heat
|
ELE18-00785
| Final | 5/24/2018 | 5/24/2018 | 5/24/2018 2:30:04 PM | P | FAIL |
|
|
Please call Shae on your way ###-####. After 1 pm would be best. If you have any questions please feel free to contact Luke ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan...1 1) panel circuits need to be properly labelled 2) bath outlet on GFCI breaker with GFCI outlet installed 3) furnace circuit shall not feed anything but furnace...dwn bath outlet 4) outlets need added within 6ft of fireplace either above cabinets or in wall
|
ELE18-00821
| Final | 5/24/2018 | 5/24/2018 | 5/24/2018 12:51:57 PM | P | FAIL |
|
|
code 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn... 1) no power in garage circuit 2) garage lights, kitchen lights no power 3) no power kitchen circuit DID NOT checkout rest of house
|
ELE18-01740
| Final | 5/24/2018 | 5/24/2018 | 5/24/2018 11:58:18 AM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Robert Murray...scheduled wrong house
|
ELE18-01948
| Final | 5/23/2018 | 5/24/2018 | 5/24/2018 11:39:35 AM | P | CANC |
|
|
Jason is our contact Phone #: ###-#### Inspection requested via web by Kelly Felin...wrong inspection...temp service inspection scheduled
|
ELE18-01948
| Temporary Service | 5/24/2018 | 5/24/2018 | 5/24/2018 11:39:01 AM | P | PASS |
|
|
Jason is our contact Phone #: ###-#### Inspection requested via web by Kelly Felin...t/s u/g new ok
|
MIS18-00193
| ELE-Conference | 5/23/2018 | 5/24/2018 | 5/24/2018 11:17:13 AM | A | FAIL |
|
|
call Kandyce when on way out ###-#### // Substandard renters complaint: fuses in kitchen keep blowing, circuits possibly overloaded, bathroom tub and sink drain slow, smoke alarms not working, general life safety issues... 1) No GFCI protection in kitchen 2) multiple cooking appliances on kitchen circuit..overloading of circuit 3) no cover on panel or proper labelling...code violation 4) panel located in closet...code violation 5) no working smoke detectors in each bedroom 6) wiring done without proper permits...code violation
pictures have been taken and stored for future
|
ELE18-01926
| Electrical Rough-In | 5/23/2018 | 5/24/2018 | 5/24/2018 10:01:22 AM | A | PASS |
|
|
Chad VanOrden is contact at ###-####. thank you. Phone #: ###-#### Inspection requested via web by Debby Pierce...wall cover ok...contact contractor and discussed code 210.71-needs to add 1 outlet for wall requirement and floor outlet requirement
|
ELE18-01816
| Electrical Rough-In | 5/23/2018 | 5/24/2018 | 5/24/2018 9:19:16 AM | A | PASS |
|
|
Please call Ryan ###-#### when you head his way. Any electrical questions, you will want to call Fred at ###-####. Thank You!! Phone #: ###-#### Inspection requested via web by Clayton Morgan...dining rm cans, living rm cans, kitchen outlets and lighting, required outlets in open walls ok, others fished outlets in
|
ELE17-03829
| Permanent Service | 5/23/2018 | 5/24/2018 | 5/24/2018 8:59:26 AM | A | PASS |
|
|
Contact is Ryan Weiderich, Gate padlock code is 1950 if needed. Phone #: ###-#### Inspection requested via web by Scott Campbell...p/s u/g new ok meter is located south west corner of property close to freeway
|
ELE18-01950
| Final | 5/24/2018 | 5/24/2018 | 5/24/2018 8:23:12 AM | A | CANC |
|
|
This Is All Ready To Go Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett...wrong inspection scheduled...temp service inspection scheduled
|
ELE18-01950
| Temporary Service | 5/24/2018 | 5/24/2018 | 5/24/2018 8:22:30 AM | A | PASS |
|
|
This Is All Ready To Go Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett...t/s o/h new ok
|
ELE18-01953
| Permanent Service | 5/24/2018 | 5/24/2018 | 5/24/2018 8:19:04 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Jason Wicks Inspection cancelled from web by: Jason Wicks
|