Inspections for the day of: Friday, May 25, 2007.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01876 Electrical Rough-In5/25/20075/25/20075/25/2007 3:41:06 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer ric ok ,talked to contr about can lights in new wine closet, said that new construction not supposed to be remodel type, need to ensure that insulation not in contact with cans that get installed, Tom is elect.
ELE07-01876 Final5/25/20075/25/20075/25/2007 3:28:39 PMPCANC
Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer wrong type inspection request, see ri
ELE07-00316 Final5/25/20075/25/20075/25/2007 2:54:36 PMPPASS
Scheduled by a contractor via Hello! on 5/25/2007 at 8:17:03 AM. Contact: ###-####. ok to final, signed occ card
ELE07-00913 Final5/25/20075/25/20075/25/2007 2:27:39 PMPPASS
Scheduled by a contractor via Hello! on 5/25/2007 at 8:16:25 AM. Contact: ###-####. ok to final, signed occ card
ELE06-02052 Final5/25/20075/25/20075/25/2007 2:02:20 PMPPASS
Scheduled by a contractor via Hello! on 5/25/2007 at 8:15:31 AM. Contact: ###-####. ok to final, no card to sign
ELE07-00704 Final5/25/20075/25/20075/25/2007 1:23:17 PMPFAIL
craig; Phone #: ###-#### - please call for access Internet Inspection Request from: Victoria Beall called, left corr notice, nec 422.16(B)(2) disposal cord shall not be over 3', 408.4 circuit directory shall be clear, concise and direct for each ckt, 210.12(B) bedrooms shall have afci protection, 422.31(B) shall provide lockout or disconnect for hw heater, 410.8(D) shall have minimum 12" from edge of shelf to edge of fixture in closet, 406.4(D) faceplates shall allow recpts to be flush with or project from faceplate, 410(D) luminaire within 3' of shower shall be listed for wet location if subject to shower spray, BCC kitchen gfci shall operate, 3-way switch to basement shall be wired correctly, nec 110.26 shall provide clearances at garage panel, 250 shall provide grounding for garage
ELE07-01899 Final5/25/20075/25/20075/25/2007 12:24:35 PMPPASS
pat; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok to final
ELE07-01873 Conference5/24/20075/25/20075/25/2007 11:49:48 AMADONE
tom ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith talked about bringing addition up to code
ELE07-01894 Electrical Rough-In5/25/20075/25/20075/25/2007 10:35:38 AMAFAIL
###-#### Internet Inspection Request from: Todd Holbrook called, left message, left corr notice, nec 210.52(A)(2) there shall be recpt on 2' wall space(ne up br), 300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing members, 334.30 nm cable shall be stapled within 12" of panel, need to look at service when called in, check for sub-panel gnd and neut isol, range and dryer 4-wire
ELE07-01827 Electrical Rough-In5/24/20075/25/20075/25/2007 9:50:57 AMAPASS
rick - special instructions the bld is at 1115 e jefferson ; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called, ric ok
ELE07-01811 Final5/24/20075/25/20075/25/2007 9:08:30 AMAPASS
justin; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, ok to final
ELE07-01088 Electrical Rough-In5/24/20075/25/20075/25/2007 8:42:23 AMAPASS
mike Note: underground; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles west side u/g ok to cover
ELE07-01217 Final5/24/20075/25/20075/25/2007 8:11:56 AMAPASS
bruce; Phone #: ###-#### Internet Inspection Request from: Victoria Beall had elect do a couple of small fixes, ok to final, signed occ card
ELE06-03238 Final5/24/20075/25/20075/24/2007 12:52:57 PMACANC
David ; Phone #: ###-#### Internet Inspection Request from: Victoria Beall Disp set to [CANC] by a contractor via Hello! on May 24 2007 12:52PM.