Inspections for the day of: Wednesday, May 25, 2016.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Little
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM16-01902 Water Heater Final5/25/20165/25/20165/25/2016 4:36:16 PMACANC
WATER HEATER INSTALL - HOMEOWNER REQUESTS INSPECTION AS CLOSE TO NOON AS POSSIBLE. PLEASE CALL 1 HOUR PRIOR TO ARRIVAL ###-####. HOMEOWNER IS MIKE WESTOVER Phone #: ###-#### Inspection requested via web by JEREMY LINK
>I scheduled for the wrong morning. it is now scheduled for 5/26
PLM16-01849 Final5/24/20165/25/20165/25/2016 3:57:42 PMPPASS
Backfilled and backflow is certified. Call Kassy in office for questions ###-#### Phone #: ###-#### Inspection requested via web by Kassy Goodwin
PLM16-01890 Plumbing Rough-in5/25/20165/25/20165/25/2016 3:55:16 PMPPASS
Please contact Bill Kirk for site access. Bill Kirk ###-#### Phone #: ###-#### Inspection requested via web by Joshua Bennett
PLM16-01882 Water and/or Sewer5/24/20165/25/20165/25/2016 3:43:09 PMPFAIL
Contact Luis Ornelas @ ###-#### for any questions. Phone #: ###-#### Inspection requested via web by Accounts Payable
>need drain down valve
PLM16-01658 Plumbing Rough-in5/24/20165/25/20165/25/2016 3:06:35 PMPPASS
Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM16-01898 Sprinkler (Final)5/25/20165/25/20165/25/2016 2:29:12 PMPPASS
Phone #: ###-#### Inspection requested via web by Darrell Roark
PLM16-01685 Water and/or Sewer5/24/20165/25/20165/25/2016 2:04:08 PMAFAIL
Shelly Phone #: ###-####
>verify abs glue is not cpvc glue, no glue can onsite
>transition glue joint needs to be outside of building.
>re test
> need BLD permit
PLM16-01208 Final5/25/20165/25/20165/25/2016 2:03:05 PMPPASS
Phone #: ###-#### Inspection requested via web by Scott Wickstrom
PLM16-01165 Final5/24/20165/25/20165/25/2016 1:39:29 PMPPASS
Inspection requested via web by Brian Johansen
PLM16-00225 Final5/24/20165/25/20165/25/2016 12:27:14 PMAPASS
2125 ENTER Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM16-01112 Final5/25/20165/25/20165/25/2016 12:10:33 PMAPASS
Garage code is 1001. Phone #: ###-#### Inspection requested via web by David Stephenson
PLM16-01894 Plumbing Rough-in5/25/20165/25/20165/25/2016 12:10:18 PMPPASS
Ready now. Phone #: ###-#### Inspection requested via web by David Stephenson
PLM16-00803 Water and/or Sewer5/24/20165/25/20165/25/2016 11:57:07 AMAPASS
Phone #: ###-#### Inspection requested via web by Rob Bristol
PLM16-01049 Final5/24/20165/25/20165/25/2016 11:56:49 AMAPASS
Phone #: ###-#### Inspection requested via web by Rob Bristol
PLM16-01875 DOC - Permit Finaled5/25/20165/25/20165/25/2016 11:38:16 AMPPASS
PLM16-01875 Med/Gas Systems5/24/20165/25/20165/25/2016 11:38:06 AMAPASS
Kelly Phone #: ###-####
>20lb test ok
PLM16-01500 Water Heater Final5/24/20165/25/20165/25/2016 11:20:09 AMAPASS
Patrica home until 12:30
PLM16-01850 Water and/or Sewer5/24/20165/25/20165/25/2016 11:00:29 AMAFAIL
Phone #: ###-#### Inspection requested via web by Vicki Tallent
>need 2' of coverage over pipe at house
>remove boulder sitting on sewer pipe
>properly bed sewer
>uncover to tie in
>uncover water
PLM16-01878 Water Heater Final5/24/20165/25/20165/25/2016 10:57:29 AMAFAIL
WATER HEATER INSTALL - PLEASE CALL JULIE KEYE 30 MINUTES PRIOR TO ARRIVAL. Phone #: ###-#### Inspection requested via web by JEREMY LINK
>T&P is back graded, spin T&P to eliminate backgrade so pipe does not sit full of water if dischage occurs.
>send pic of repair.












PLM16-01681 Sprinkler (Final)5/24/20165/25/20165/25/2016 10:30:20 AMAFAIL
Chuck Phone #: ###-####
>uncover complete tee at tie in
>insert fitting is not pushed in all the way and leaking at tie in
>line from backflow to drain must be graded to drain down
>certify RPBA
>each barbed ftg needs two clamps
PLM16-01153 Final5/24/20165/25/20165/25/2016 10:09:57 AMAFAIL
Key is hidden above front door in ceiling. Phone #: ###-#### Inspection requested via web by chris mcdaniel
>need to add an expansion tank since backflow was added
>Add ASSE 1070 conforming tempering device to lav per 413.1 ISPC
PLM16-01876 Water Heater Final5/24/20165/25/20165/25/2016 9:16:42 AMAPASS
Please call ahead Glad Perrault ###-#### Phone #: ###-#### Inspection requested via web by Chris Field
PLM16-01760 Plumbing Rough-in5/24/20165/25/20165/25/2016 8:56:59 AMAPASS
Please call for key code access number if no one is there. Thanks. ###-#### Phone #: ###-#### Inspection requested via web by Josh Johnson
PLM16-01877 Final5/24/20165/25/20165/25/2016 8:32:01 AMAFAIL
Carl Phone #: ###-####
>need to pipe wh pan drain
>T&P needs a 1" airgap or pipe to garge floor so it will be noticed if discharge is occuring.
PLM16-01864 Groundwork5/24/20165/25/20165/25/2016 8:09:38 AMAPASS
ANY QUESTIONS CALL TOM ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann