ELE12-02116
| ELE-Aging Inspection | 5/25/2016 | 5/25/2016 | 5/31/2016 8:02:49 AM | | CANC |
|
|
too busy
|
ELE10-01957
| ELE-Aging Inspection | 5/25/2016 | 5/25/2016 | 5/31/2016 7:58:39 AM | | CANC |
|
|
too busy
|
ELE16-01283
| Final | 5/25/2016 | 5/25/2016 | 5/25/2016 2:21:45 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn 110.7 Wiring integrity kitchen lights in-op 406.5 Receptacles shall be rigidly mounted(recept in garage loose)
|
ELE16-01176
| Conference | 5/24/2016 | 5/25/2016 | 5/25/2016 1:28:27 PM | P | PASS |
|
|
call to set up meeting time with Steve. Phone #: ###-#### Inspection requested via web by steve sellers EC will provide a equipment grounding conducor with a ear-reaversible crimp to j-box and verify bonding jumper witch looks to established in meter proir to p/s inspection
|
ELE16-01612
| Electrical Rough-In | 5/25/2016 | 5/25/2016 | 5/25/2016 12:50:46 PM | P | PASS |
|
|
Tenant improvement Phone #: ###-#### Inspection requested via web by Steve Craig Walls and hard lids in back rooms only ok cover
|
ELE16-01162
| Final | 5/25/2016 | 5/25/2016 | 5/25/2016 12:49:47 PM | P | PASS |
|
|
Ken Phone #: ###-#### Sign final ok
|
ELE16-01480
| Final | 5/25/2016 | 5/25/2016 | 5/25/2016 12:49:16 PM | P | PASS |
|
|
Corrections have been made Phone #: ###-#### Inspection requested via web by Matthew White Downspout was replaced with PVC type, corrections fixed final ok
|
ELE16-00702
| Permanent Service | 5/24/2016 | 5/25/2016 | 5/25/2016 10:42:44 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Celinda Winters EC will make provision for final that planter in front of main disc. will be flush with top of curb for work space platform. p/s u/g n ok
|
ELE16-01661
| Conference | 5/24/2016 | 5/25/2016 | 5/25/2016 9:45:00 AM | A | DONE |
|
|
Theresa// please call ahead Phone #: ###-#### Discussed code requirements for a detached buidling/ feeding the shop with THHN or UF and GFCI for receptacles in garage and WR in wp outlets. Grounding electrodes to be installed and isolating grounding and grounded conductors in sub panel in garage.
|
ELE16-00430
| Final | 5/24/2016 | 5/25/2016 | 5/25/2016 9:02:20 AM | A | FAIL |
|
|
Inspection requested via web by steve ragan 314,25 cover required for man hole cover on light pole
|
ELE16-01413
| Final | 5/24/2016 | 5/25/2016 | 5/25/2016 8:26:54 AM | A | PASS |
|
|
contact is Chad VanOrden at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce Final ok
|