Inspections for the day of: Thursday, May 26, 2005.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01814 Conference5/26/20055/26/20055/26/2005 4:34:21 PMPDONE
jeremy ###-#### talked about u/g under slab and pullbox
ELE05-01682 Electrical Rough-In5/26/20055/26/20055/26/2005 4:33:31 PMPNR
Phone #: ###-#### Internet Inspection Request from: Tyler Bowen interior walls only ok to cover
ELE05-01744 Electrical Rough-In5/26/20055/26/20055/26/2005 3:46:17 PMPPASS
###-#### Andy\\ Pool Bonding called contr to bond both rails in bases ok to cover bonds
ELE05-01230 Final5/26/20055/26/20055/26/2005 3:40:03 PMPFAIL
Scheduled by a contractor via Hello! on 5/26/2005 at 10:33:32 AM. met with elect, left corr. notice, 110.26(A) (1) and (2) work space shall be provided about equipment for width and depth, 408.7 unused openings shall be closed in panelboard
ELE05-01831 Electrical Rough-In5/24/20055/26/20055/26/2005 2:43:36 PMPPASS
underground inspection// john ###-#### pool bond u/g cnd ok to cover
ELE05-00717 Final5/26/20055/26/20055/26/2005 2:05:35 PMPPASS
alex; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to final
ELE05-01399 Electrical Rough-In5/26/20055/26/20055/26/2005 1:35:33 PMPPASS
underground insp for parking lot skip ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok to cover u/g for parking lot
ELE05-01097 Final5/26/20055/26/20055/26/2005 1:06:37 PMPFAIL
Scheduled by a contractor via Hello! on 5/26/2005 at 7:55:45 AM. Contact: ###-####. called, left message, left corr notice, 406.4(B) recpts shall be held rigidly, 410.12 outlet shall be covered(mbr light), 210.8(A)(2) garage gfci shall reset to c
ELE05-01468 Final5/26/20055/26/20055/26/2005 10:44:55 AMAPASS
final on pool enclosure; Phone #: ###-#### Internet Inspection Request from: todd hall ok to final, signed card
ELE04-02595 Final5/26/20055/26/20055/26/2005 10:44:13 AMAPASS
final for entire project; Phone #: ###-#### Internet Inspection Request from: todd hall ok to final, signed occ card
ELE05-01845 Permanent Service5/25/20055/26/20055/26/2005 10:10:52 AMACANC
mike ###-#### see cloned inspection
ELE05-01840 Permanent Service5/25/20055/26/20055/26/2005 8:46:44 AMAPASS
chuck space #107; Phone #: ###-#### Internet Inspection Request from: Barbara Moore p/s u/g exst meter ok
ELE05-01575 Final5/25/20055/26/20055/26/2005 8:28:51 AMANR
dennis ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie called contr, recpts not mounted, no covers, water heater not hooked up, ceiling fan open. Told to call when ready.
ELE05-00212 Final5/25/20055/26/20055/26/2005 8:06:12 AMAPASS
alan; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to final
ELE05-00987 Final5/25/20055/26/20055/26/2005 8:04:37 AMAPASS
alan; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to final
ELE05-00986 Final5/25/20055/26/20055/26/2005 8:03:56 AMAPASS
alan; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to final
ELE05-01845 Electrical Rough-In5/26/20055/26/20055/26/2005 12:00:00 AMAPASS
mike ###-#### ok to cover u/g from pedestal to foundation