Inspections for the day of: Friday, May 26, 2006.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01561 ELE-Aging Inspection5/26/20065/26/20066/2/2006 8:48:44 AM DONE
called left message, they need to follow up on permits and contact me
ELE05-01707 Final5/24/20065/26/20065/26/2006 4:11:16 PMPFAIL
Scheduled by a contractor via Hello! on 5/24/2006 at 9:42:43 AM. Contact: ###-####. called there is no 1700 w westgate
ELE06-01927 Temporary Service5/26/20065/26/20065/26/2006 3:27:13 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Shaun Kirkman corr clean dirt from t/s called left message
ELE06-00125 Final5/26/20065/26/20065/26/2006 2:45:37 PMPPART
ryan; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles t/o ok card signed
ELE05-02785 Final5/26/20065/26/20065/26/2006 2:00:50 PMPFAIL
Scheduled by a contractor via Hello! on 5/26/2006 at 9:28:54 AM. Contact: ###-####. met owner he added stairs needs lighting and 3 ways for them
ELE06-00214 Final5/25/20065/26/20065/26/2006 1:26:23 PMAPASS
jamie; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
ELE06-00291 Final5/26/20065/26/20065/26/2006 12:49:16 PMPPASS
Chuck; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
p/s ok for final only needs to call in permit for interior wiring for final of office space called left message
ELE06-01378 Rough-In Permanent Service5/25/20065/26/20065/26/2006 12:33:08 PMAFAIL
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot corr. called
needs nail plates and complete wiring in dropped ceil areas
ELE06-01205 Rough-In Permanent Service5/23/20065/26/20065/26/2006 11:43:15 AMAFAIL
jason appleman; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa Had conference with owner. Did not post correction.
ELE05-04252 Electrical Rough-In5/26/20065/26/20065/26/2006 10:48:23 AMAPART
Scheduled by a contractor via Hello! on 5/26/2006 at 7:21:43 AM. Contact: ###-####. u/g for sign and flag pole ok
ELE05-00462 Final5/23/20065/26/20065/26/2006 10:16:53 AMAFAIL
chad ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
250.148 grd metal cutin box kit,314.17(B) needs conn for cutin box, 110.3(A) shall replace plastic box damaged back side peninsular counter, 210.52(B) shall install required small appliance branch circuits for kit ,din as code noted states min 2 circuits shall serve countertops outlets 408.4 panel schedule shall match circiut numbers on deadfront and be specfic as to purpose cow
reinspection fee called
ELE06-00609 Electrical Rough-In5/25/20065/26/20065/26/2006 9:12:40 AMAPASS
ron or al - grid ceiling inspection; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
ELE06-01850 Temporary Service5/26/20065/26/20065/26/2006 8:21:33 AMAPASS
t/s o/h new ok
ELE06-01919 Rough-In Permanent Service5/25/20065/26/20065/26/2006 8:10:01 AMAPASS
1st in am for electrode ok p/s o/h rec. ok
ELE06-01807 Electrical Rough-In5/25/20065/26/20065/26/2006 7:46:08 AMAPART
Please call Greg to set up a early a.m inspection due to working graveyard shift. Thanks! Greg ###-####; Phone #: ###-#### Internet Inspection Request
from: Steve Syltie u/g ok