Inspections for the day of: Friday, May 26, 2006.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-01549 Final5/26/20065/26/20065/26/2006 4:23:27 PMPPASS
Phone #: ###-#### Internet Inspection Request from: JENNY EMEL signed card, ok to final
ELE06-01657 Final5/26/20065/26/20065/26/2006 3:51:01 PMPPASS
Phone #: ###-#### Internet Inspection Request from: JENNY EMEL signed occ card, ok to final
ELE06-00790 Permanent Service5/26/20065/26/20065/26/2006 3:01:37 PMPPASS
Questions call Mike @ ###-#### - scheduled by Heather Packer w/ Doherty; Phone #: ###-#### Internet Inspection Request from: Heather Packer p/s exst meter pak, n ok
ELE06-00159 Electrical Rough-In5/26/20065/26/20065/26/2006 2:48:12 PMPPASS
ok to cover floor heat, need to check for j-boxes in basement, and 220v on gfci 4 places
ELE06-00656 ELE-Aging Inspection5/26/20065/26/20065/26/2006 2:41:56 PM DONE
suc
ELE06-00657 ELE-Aging Inspection5/26/20065/26/20065/26/2006 2:30:34 PM DONE
suc
ELE06-01225 Final5/26/20065/26/20065/26/2006 1:35:59 PMPPASS
james - 6th floor suite 620; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles signed occ card, ok to final, recpts working
ELE06-00719 Final5/25/20065/26/20065/26/2006 12:51:03 PMAPASS
Phone #: ###-#### Internet Inspection Request from: Daryl DeGrange ok to final
ELE06-01687 Final5/26/20065/26/20065/26/2006 12:07:36 PMPPASS
ok to fina
ELE06-00713 Final5/25/20065/26/20065/26/2006 10:49:42 AMANR
please call if you have any ?'s I don't think the house numbers are on yet?; Phone #: ###-#### Internet Inspection Request from: Shane Vigil called contr, all ok except disposal, a/c, dishwasher, and closet lite. told to call when ready
ELE06-01912 Rough-In Permanent Service5/25/20065/26/20065/26/2006 10:07:55 AMAFAIL
need inspection on new service plus wiring in garage.Call Andy @###-#### if any questions Internet Inspection Request from: Andy Rose called contr, left corr notice, NEC 230.24(B)(4) service drop conductors shall be min. 18' over public alley, 300.4(D) nm cable shall be 1 1/4" from edge of framing member,BCC all make-up shall be done without any devices installed
ELE06-01922 Electrical Rough-In5/25/20065/26/20065/26/2006 9:33:57 AMAPASS
###-#### - Jerry Note: bond and underground cover pool pool bond and u/g ok to cover
ELE06-01627 Rough-In Permanent Service5/25/20065/26/20065/26/2006 9:13:00 AMAPASS
As early as possible please.; Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton ok to cover u/g, north light base, ttransf to bldg
ELE06-00339 Final5/25/20065/26/20065/26/2006 8:31:12 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Danette Brookshire called contr, left message, left corr notice, NEC 210.52(B)(2) small appliance branch circuits shall have no other outlets, 410.8(D) closet lite shall be 12" from edge of storage space, 406.4 recpts shall be securely fastened in place, 210.52(A)(2) wall space over 2' shall have recpt installed-dining area