ELE09-00850
| Final | 5/26/2009 | 5/26/2009 | 5/26/2009 3:39:02 PM | P | PASS |
|
|
Final on permanent service. ###-#### Phone #: ###-#### Internet Inspection Request from: Randy Fletcher
|
ELE09-00252
| Final | 5/26/2009 | 5/26/2009 | 5/26/2009 3:38:42 PM | P | PASS |
|
|
Kim Phone #: ###-#### ok
|
ELE09-00102
| Final | 5/26/2009 | 5/26/2009 | 5/26/2009 2:34:24 PM | P | PASS |
|
|
Sean Phone #: ###-####
|
ELE09-00891
| Electrical Rough-In | 5/26/2009 | 5/26/2009 | 5/26/2009 1:46:42 PM | P | PART |
|
|
cover for walls only please-Shane Phone #: ###-#### walls and rest rm hard ceiling
|
ELE09-00786
| Final | 5/22/2009 | 5/26/2009 | 5/26/2009 1:11:15 PM | P | PASS |
|
|
Mark Phone #: ###-####
|
ELE09-00786
| Permanent Service | 5/26/2009 | 5/26/2009 | 5/26/2009 1:10:53 PM | P | PASS |
|
|
p/s o/h rec. ok
|
ELE09-00894
| Final | 5/26/2009 | 5/26/2009 | 5/26/2009 10:27:26 AM | A | FAIL |
|
|
Call for access ahead of time. Phone #: ###-#### Internet Inspection Request from: Cevyn Recla called needs grding and bonding , 4 wire feed to range
|
ELE09-00853
| Permanent Service | 5/22/2009 | 5/26/2009 | 5/26/2009 10:02:10 AM | A | FAIL |
|
|
clyde Phone #: ###-#### called left message no grd to water, and no access to house
|
ELE09-00102
| Final | 5/24/2009 | 5/26/2009 | 5/26/2009 9:11:15 AM | A | FAIL |
|
|
please renspect, thank you Phone #: ###-#### Internet Inspection Request from: Sean Peltier no power to 1/2 of basement, called
|
ESC09-00111
| General Inspection | 5/26/2009 | 5/26/2009 | 5/26/2009 8:31:27 AM | A | PASS |
|
|
ok
|
ELE09-00890
| Rough-In Permanent Service | 5/22/2009 | 5/26/2009 | 5/26/2009 8:30:54 AM | A | FAIL |
|
|
Dino Phone #: ###-#### called corr. 210.52(A&C) needs receps for wall space fixed panel patio door and countertop in din rm 334.23 protect all cables 6ft of attic access, 314.17&362.6 bushings for cables, and conn for ENT at low voltage cabinet
|