Inspections for the day of: Thursday, May 26, 2011.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Johnson
TitlePLM-INSPECTOR
Phone #794-9476
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM11-00925 Water and/or Sewer5/25/20115/26/20115/26/2011 4:48:08 PMPPASS
john - late as possible please Phone #: ###-####
PLM11-00925 DOC - Permit Finaled5/26/20115/26/20115/26/2011 4:47:47 PMPPASS
john - late as possible please Phone #: ###-####
PLM11-00575 Plumbing Rough-in5/25/20115/26/20115/26/2011 3:51:30 PMPPASS
please call Jeremy with any questions! Phone #: ###-#### >> Inspection requested via web by Nicholas Paige
PLM11-00922 Sprinkler (Final)5/25/20115/26/20115/26/2011 2:39:59 PMAPART
robert Phone #: ###-#### need P V B tested and certified
PLM09-01956 Plumbing Rough-in5/26/20115/26/20115/26/2011 2:37:26 PMPFAIL
James Phone #: ###-#### need to repipe vent for water closet to two inch with two inch vent through roof support abs every 4 feet need to repipe water line,s to front of 2x6 wall replace fernco coupling with shielded band home owner to recall when ready
PLM11-00904 Plumbing Rough-in5/25/20115/26/20115/26/2011 1:53:10 PMPNR
JOB # 15916. Phone #: ###-#### >> Inspection requested via web by Ann Marie Reyes not ready
PLM11-00599 Plumbing Rough-in5/25/20115/26/20115/26/2011 1:20:45 PMPFAIL
Early pm would be preferrable if possible. Contact Aaron with any questions. Thanks Phone #: ###-#### >> Inspection requested via web by Kirk Johns need to correct leak,s in D W V need to replace 4x2 san tee with 4x2 combo,s for urinal connection need to replace galv. 90 with approved durham drainage 90 on urinal,s and drinking fountain need mid story support,s on main 4 inch stack .need base of stack cleanout installed on main 4 inch waste stack.
PLM11-00932 Plumbing Rough-in5/26/20115/26/20115/26/2011 12:45:40 PMPPASS
rough in inspection........ Phone #: ###-#### >> Inspection requested via web by Carol Hazen
PLM11-00273 PLM-Aging Inspection5/26/20115/26/20115/26/2011 12:41:28 PM PASS
PLM11-00792 Water and/or Sewer5/25/20115/26/20115/26/2011 12:41:12 PMAPART
John Phone #: ###-#### two inch water line test ok need to extend water line above finish grade in building no hose clamp type joint,s allowed under concret slab in building
PLM11-00817 Final5/25/20115/26/20115/26/2011 10:22:23 AMAPART
Phone #: ###-#### >> Inspection requested via web by bob pond need to install a spill-proof P V B on hose reel need to finish instalation of hand sink on west wall contractor to recall when ready oked temp.
PLM11-00779 Final5/25/20115/26/20115/26/2011 9:04:00 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Travis Baker
PLM11-00870 Plumbing Rough-in5/25/20115/26/20115/26/2011 8:37:56 AMAPART
groundwork for floor drain in pool equipment room test ok ok to cover