MEC20-02041
| Rough-in | 5/25/2020 | 5/26/2020 | 5/26/2020 3:41:42 PM | P | PART |
|
|
Please call Chris Matos prior to arrival to ensure ready for inspection. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby - line sets and condensate lines partial R/I only ok - project looks to still need exhaust fans installed, electric heaters and possibly a fireplace all done by others. hvac contractor is only doing the mini split - all other work will need to be seen before R/I cover is given
|
MEC20-01719
| Final | 5/26/2020 | 5/26/2020 | 5/26/2020 3:29:54 PM | P | PASS |
|
|
PLEASE CALL TENANT TERRA WHEN 30-45 MINS IN ROUTE FOR AFTERNOON ARRIVAL EXPECTANCY Phone #: ###-#### Inspection requested via web by Rick Montgomery
|
MEC20-01689
| Final | 5/19/2020 | 5/26/2020 | 5/26/2020 3:00:23 PM | P | PASS |
|
|
Please call owner when in route to home at ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd - furnace ac coil co ok
|
MEC20-01708
| Final | 5/22/2020 | 5/26/2020 | 5/26/2020 2:37:58 PM | P | PASS |
|
|
Homeowner Josh Smith ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - A/C only co ok
|
MEC20-01039
| Final | 5/26/2020 | 5/26/2020 | 5/26/2020 2:26:39 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jose Lagunas - final ok
|
MEC20-01393
| Final | 5/26/2020 | 5/26/2020 | 5/26/2020 1:43:39 PM | P | PASS |
|
|
This is for unit J105. Homeowner Gail Haldeman ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - air handler coil HP ok
|
MEC20-01428
| Rough-in | 5/26/2020 | 5/26/2020 | 5/26/2020 1:29:02 PM | P | PASS |
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney - R/I ok
|
MEC20-01428
| Pressure Test | 5/26/2020 | 5/26/2020 | 5/26/2020 1:28:49 PM | P | PASS |
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney - 20lb gas test ok - tagged meter location
|
MEC20-01955
| Final | 5/19/2020 | 5/26/2020 | 5/26/2020 1:18:57 PM | P | PASS |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - final ok
|
MEC20-01188
| Final | 5/20/2020 | 5/26/2020 | 5/26/2020 12:04:55 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - range hood vent not installed - A/C doesn't match Man J
|
MEC20-01372
| Final | 5/20/2020 | 5/26/2020 | 5/26/2020 12:04:41 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - range hood vent not installed - A/C doesn't match Man J
|
MEC20-02038
| Final | 5/23/2020 | 5/26/2020 | 5/26/2020 11:14:04 AM | A | PASS |
|
|
key in exterior GFI Phone #: ###-#### Inspection requested via web by jamie berg - final ok
|
MEC20-01978
| Final | 5/19/2020 | 5/26/2020 | 5/26/2020 10:51:44 AM | A | PASS |
|
|
Electrician is also coming that same day. Homeowner would really like it to be this day in the morning. Please let me know if this can''t be accomplished. Phone #: ###-#### Inspection requested via web by Ashley Van Cleave - final ok
|
MEC20-02034
| Rough-in | 5/22/2020 | 5/26/2020 | 5/26/2020 10:24:35 AM | A | FAIL |
|
|
Doug Phone #: ###-#### - need to update Man J to match equipment being installed. One indoor coil is being added downstairs - bathroom exhaust fan needs to be energy star rated - provide make up air opening from bathroom to open space
|
MEC20-01086
| Final | 5/24/2020 | 5/26/2020 | 5/26/2020 9:38:56 AM | A | PASS |
|
|
Garage code 0410 Upstairs door code 123678 Phone #: ###-#### Inspection requested via web by Kyle Flanagan - final ok
|
MEC20-01108
| Final | 5/19/2020 | 5/26/2020 | 5/26/2020 9:24:44 AM | A | FAIL |
|
|
Please call Andrew Jacobs prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - Mini split ok - need to see an electrical permit issued for new system
|
MEC20-01100
| Conference | 5/22/2020 | 5/26/2020 | 5/26/2020 9:02:26 AM | A | PASS |
|
|
8:30 am Duct Blast Phone #: ###-#### Inspection requested via web by Debbie Marino - duct blast ok - need air balance done for final
|
MEC20-01962
| Rough-in | 5/22/2020 | 5/26/2020 | 5/26/2020 8:53:20 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino - finish insulation shield in garage area - several locations need line set insulation repaired
|
MEC20-01962
| Pressure Test | 5/22/2020 | 5/26/2020 | 5/26/2020 8:52:37 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino - 20lb gas test ok - tagged meter location
|
MEC20-02026
| Final | 5/22/2020 | 5/26/2020 | 5/26/2020 8:40:19 AM | P | CANC |
|
|
Please call home owner when on way. Kolleen ###-#### Phone #: ###-#### >> Inspection requested via web by max sanders Inspection cancelled from web by: max sanders
|
MEC19-01907
| Mec-Aging Inspection | 5/26/2020 | 5/26/2020 | 5/26/2020 8:02:28 AM | | PASS |
|
|
Doc Permit Expired ok
|
MEC19-01907
| DOC - Permit Expired | 5/26/2020 | 5/26/2020 | 5/26/2020 8:02:20 AM | A | PASS |
|
|
Doc Permit Expired ok permit not active
|
MEC19-04827
| Mec-Aging Inspection | 5/26/2020 | 5/26/2020 | 5/26/2020 8:01:11 AM | | PASS |
|
|
Permit has not been active since 10-25-19. Schedule final inspection with owner if work is finished.
|
MEC19-04831
| Mec-Aging Inspection | 5/26/2020 | 5/26/2020 | 5/26/2020 8:00:20 AM | | PASS |
|
|
Doc Permit Finaled ok
|
MEC19-04831
| DOC - Permit Finaled | 5/26/2020 | 5/26/2020 | 5/26/2020 8:00:12 AM | A | PASS |
|
|
Doc Permit Finaled ok
|
MEC19-01886
| DOC - Permit Expired | 5/26/2020 | 5/26/2020 | 5/26/2020 7:57:41 AM | A | PASS |
|
|
Doc Permit Expired ok permit not active
|
MEC19-04808
| DOC - Permit Finaled | 5/26/2020 | 5/26/2020 | 5/26/2020 7:56:43 AM | A | PASS |
|
|
Doc Permit Finaled ok
|