Inspections for the day of: Friday, May 27, 2005.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01861 Electrical Rough-In5/26/20055/27/20055/31/2005 4:05:04 AMPPASS
trench inspection ###-#### alloway electric ok to cover trench to exst light. called contr to say ok to cover, left sticker
ELE05-01872 Rough-In Permanent Service5/27/20055/27/20055/27/2005 3:41:55 PMPNR
clyde-- ###-#### not done
ELE05-01230 Final5/27/20055/27/20055/27/2005 3:18:15 PMPPASS
Scheduled by a contractor via Hello! on 5/27/2005 at 9:50:21 AM. ok to cover and final
ELE05-01871 Rough-In Permanent Service5/27/20055/27/20055/27/2005 2:20:02 PMPPASS
###-#### clyde ric ok p/s u/g n ok
ELE05-01883 Permanent Service5/27/20055/27/20055/27/2005 12:41:03 PMPPASS
###-#### barbara p/s o/h n ok
ELE05-01870 Rough-In Permanent Service5/27/20055/27/20055/27/2005 11:47:19 AMPPASS
clyde ###-#### left survey, ric ok, p/s u/g n ok
ELE05-01777 Temporary Service5/27/20055/27/20055/27/2005 11:46:00 AMPFAIL
Scheduled by a contractor via Hello! on 5/27/2005 at 8:20:20 AM. 110.12(C) there shall be no broken parts, 200.6 grounded conductor shall be identified, met with contractor, left corr notice, fee due
ELE05-01779 Temporary Service5/27/20055/27/20055/27/2005 11:44:06 AMPFAIL
Scheduled by a contractor via Hello! on 5/27/2005 at 8:23:17 AM. 110.12(C) there shall be no broken parts, met and told contractor, left corr notice, fee due
ELE05-01778 Temporary Service5/27/20055/27/20055/27/2005 11:42:10 AMPPASS
Scheduled by a contractor via Hello! on 5/27/2005 at 8:21:51 AM. t/s u/g n ok
ELE05-01776 Temporary Service5/27/20055/27/20055/27/2005 11:41:33 AMPPASS
Scheduled by a contractor via Hello! on 5/27/2005 at 8:18:13 AM. Contact: ###-####. t/s u/g n ok
ELE05-01780 Temporary Service5/27/20055/27/20055/27/2005 11:40:48 AMPPASS
Scheduled by a contractor via Hello! on 5/27/2005 at 8:24:33 AM. t/s u/g n ok
ELE05-01876 Temporary Service5/27/20055/27/20055/27/2005 10:56:20 AMPPASS
###-#### - clyde t/s u/g n ok
ELE05-01781 Temporary Service5/27/20055/27/20055/27/2005 10:52:58 AMPPASS
Scheduled by a contractor via Hello! on 5/27/2005 at 8:25:50 AM. t/s u/g n ok
ELE05-00373 Final5/26/20055/27/20055/27/2005 10:22:35 AMAPASS
chris; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr to hook up a/c and fix recpt for micro-wave
ELE05-01837 Temporary Service5/26/20055/27/20055/27/2005 9:13:13 AMAPASS
rick; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa corrections made, t/s u/g n ok
ELE05-01835 Rough-In Permanent Service5/25/20055/27/20055/27/2005 8:54:12 AMAPASS
katie; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie called contractor, left message, left survey, 314.20 box shall be flush with finished surface ric ok, p/s o/h n ok
ELE05-01862 Final5/26/20055/27/20055/27/2005 8:07:05 AMAPASS
We wired in a new 120 volt duplex receptacle inside the Yellow pump shed, which is located between 9123 & 9147 W. Tudor Ct.,in culdesac. Pump shed is unlocked for your access.Thanks!!! Dan; Phone #: ###-#### Internet Inspection Request from: Dan Mitc