ELE09-00426
| ELE-Aging Inspection | 5/27/2010 | 5/27/2010 | 6/3/2010 6:27:10 AM | | DONE |
|
|
suc
|
ELE08-01084
| ELE-Aging Inspection | 5/27/2010 | 5/27/2010 | 6/1/2010 7:30:59 AM | | DONE |
|
|
see doc expire
|
ELE08-01014
| ELE-Aging Inspection | 5/27/2010 | 5/27/2010 | 6/1/2010 7:28:53 AM | | DONE |
|
|
see doc expire
|
ELE10-00626
| Electrical Rough-In | 5/27/2010 | 5/27/2010 | 5/28/2010 7:59:04 AM | P | CANC |
|
|
Potting Compound Thanks Inspection requested from web by: Lynn Cable Phone #: ###-#### see 5-28-10 response
|
ELE10-01168
| Rough-In Permanent Service | 5/27/2010 | 5/27/2010 | 5/28/2010 7:43:59 AM | P | PASS |
|
|
Inspection requested from web by: Alan Lusk Phone #: ###-#### corrections made, ric ok, p/s u/g n ok
|
ELE06-03661
| ELE-Aging Inspection | 5/27/2010 | 5/27/2010 | 5/28/2010 6:35:08 AM | | DONE |
|
|
see doc expire
|
ELE06-03306
| ELE-Aging Inspection | 5/27/2010 | 5/27/2010 | 5/27/2010 3:46:43 PM | | DONE |
|
|
see doc expire
|
ELE06-03306
| DOC - Permit Expired | 5/27/2010 | 5/27/2010 | 5/27/2010 3:46:32 PM | P | PASS |
|
|
no activity
|
ELE06-02858
| DOC - Permit Expired | 5/27/2010 | 5/27/2010 | 5/27/2010 3:27:39 PM | P | PASS |
|
|
no activity
|
ELE10-01157
| Rough-In Permanent Service | 5/26/2010 | 5/27/2010 | 5/27/2010 3:24:57 PM | P | FAIL |
|
|
Inspection requested from web by: daniel bibikov Phone #: ###-#### called, corrections given to contractor, nailplates, receptacle spacing 3 places, attic access
|
ELE10-00777
| Final | 5/27/2010 | 5/27/2010 | 5/27/2010 2:30:01 PM | P | PASS |
|
|
Inspection requested from web by: Rowdy Monroe Phone #: ###-#### called, ok to final
|
ELE10-01059
| Permanent Service | 5/26/2010 | 5/27/2010 | 5/27/2010 1:33:39 PM | A | PASS |
|
|
Service inspection Inspection requested from web by: jon gleason Phone #: ###-#### p/s, exst rack, n, ok
|
ELE09-02278
| Final | 5/26/2010 | 5/27/2010 | 5/27/2010 1:01:26 PM | P | PART |
|
|
Contact: Casey Wilde Inspection requested from web by: Deb Gooden Phone #: ###-#### need to see fixtures to hang, schedules, ko's elev area, strapping, cover plates switches, receptacles, signed t/o card
|
ELE09-01040
| Final | 5/26/2010 | 5/27/2010 | 5/27/2010 12:12:28 PM | A | PASS |
|
|
Bill Davis Phone #: ###-#### ok to final
|
ELE10-01159
| Final | 5/27/2010 | 5/27/2010 | 5/27/2010 11:35:22 AM | P | CANC |
|
|
Inspection requested from web by: jon gleason Phone #: ###-#### wrong type request, see ri
|
ELE10-01159
| Electrical Rough-In | 5/27/2010 | 5/27/2010 | 5/27/2010 11:22:22 AM | A | PASS |
|
|
Inspection requested from web by: jon gleason Phone #: ###-#### ok to cover u/g only pump to building
|
ELE10-00823
| Final | 5/26/2010 | 5/27/2010 | 5/27/2010 11:14:31 AM | A | PASS |
|
|
garage code is 31629 Inspection requested from web by: Stephen Kren Phone #: ###-#### ok to final
|
ELE10-01166
| Rough-In Permanent Service | 5/26/2010 | 5/27/2010 | 5/27/2010 10:39:23 AM | A | FAIL |
|
|
jim Phone #: ###-#### called, left correction notice, BC shall provide correct address- builder said this was 1683, not 1681, NEC 314.20 in combustible material, boxes shall be flush with finished surface at garage, 312.5 all conductors entering enclosures shall have abrasion protection, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 334.23 cables in accessible attics shall comply with 320.23, 250.28(A) shall provide main bonding jumper, 210.52(A)(1) shall provide convenience receptacle under counter-top, NOTE: corrections shall be made in 5 working days or further action will be taken
|
ELE10-01095
| Rough-In Permanent Service | 5/26/2010 | 5/27/2010 | 5/27/2010 9:39:31 AM | A | PASS |
|
|
rex Phone #: ###-#### corrections made ric ok, p/s u/g n ok
|
ELE10-01168
| Final | 5/26/2010 | 5/27/2010 | 5/27/2010 9:16:53 AM | A | CANC |
|
|
Inspection requested from web by: Alan Lusk Phone #: ###-#### wrong type request, see rip
|
ELE10-01168
| Rough-In Permanent Service | 5/27/2010 | 5/27/2010 | 5/27/2010 9:16:35 AM | A | FAIL |
|
|
Inspection requested from web by: Alan Lusk Phone #: ###-#### called, left correction notice, NEC 224.23 cables in accessible attics shall comply with 320.23, note corrections shall be made wthin 5 working days or further action will be taken
|
ELE10-01169
| Electrical Rough-In | 5/26/2010 | 5/27/2010 | 5/27/2010 8:34:01 AM | A | PASS |
|
|
Home owner should be at home. Inspection requested from web by: clyde smart Phone #: ###-#### ric ok
|
ELE10-01170
| Final | 5/26/2010 | 5/27/2010 | 5/27/2010 8:28:36 AM | P | CANC |
|
|
Could you please call me i should have this done late afternoon and this is an occupied residence. Please call me @###-#### Inspection requested from web by: jason shifflett Inspection cancelled from web by: jason shifflett
|
ELE10-01154
| Electrical Rough-In | 5/26/2010 | 5/27/2010 | 5/27/2010 8:11:25 AM | A | PASS |
|
|
Leo lopez Phone #: ###-#### ric ok
|
ELE10-01154
| Final | 5/27/2010 | 5/27/2010 | 5/27/2010 8:11:10 AM | A | PASS |
|
|
Leo lopez Phone #: ###-#### ok to final
|
ELE10-01158
| Electrical Rough-In | 5/26/2010 | 5/27/2010 | 5/26/2010 2:10:35 PM | A | PASS |
|
|
Kevin Phone #: ###-#### ok to cover floor heat
|