Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-00747 Final5/27/20145/27/20145/27/2014 2:12:34 PMPPASS
Phone #: ###-#### >> Inspection requested via web by steve sellers Final ok
ELE11-00931 ELE-Aging Inspection5/27/20145/27/20145/27/2014 2:05:55 PM DONE
Still under construction
ELE12-02384 Final5/27/20145/27/20145/27/2014 1:50:19 PMPPASS
Final ok
ELE14-01307 Permanent Service5/27/20145/27/20145/27/2014 1:19:13 PMPPASS
jimmy Phone #: ###-#### p/s u/g rec ok
ELE14-01307 Final5/27/20145/27/20145/27/2014 1:08:51 PMPPASS
jimmy Phone #: ###-#### Service reconnect final ok
ELE14-01337 Electrical Rough-In5/27/20145/27/20145/27/2014 12:49:52 PMPPASS
Please provide a rough-in inspection for this project. Contact Darrell with any questions. He''s a big sweetie! Have a great day! Phone #: ###-#### >> Inspection requested via web by Kevin Perez Garage rough in ok cover
ELE14-00312 Final5/27/20145/27/20145/27/2014 12:08:04 PMPPASS
House inspected on 5-22-14 but requested on wrong permit. House Final ok
ELE14-00747 Final5/26/20145/27/20145/27/2014 11:07:23 AMAFAIL
call for access Phone #: ###-#### >> Inspection requested via web by steve sellers Bonding not complete on hot tub
ELE10-01991 Final5/23/20145/27/20145/27/2014 10:38:45 AMAFAIL
Valerie-Please call prior to inspection Phone #: ###-#### 314.28- All junction boxes shall have covers.
210.8 All bathroom receptical outlets shall be GFCI protection
ELE12-02001 Final5/27/20145/27/20145/27/2014 9:58:19 AMAFAIL
210.8- All 15 and 20 amp 120 volt receptical outlets located in garage shall have GFCI protection.
406.11- All 15 and 20 amp 120 volt receptical outlets shall be tamper resistant type for residential garage.
406.5- All boxes shall have cover plates.
ELE13-03546 Electrical Rough-In5/23/20145/27/20145/27/2014 9:27:25 AMAPASS
re-inspect for partial ceiling basement Phone #: ###-#### Basement hard lid rough in ok cover