ELE14-01312
| Electrical Rough-In | 5/26/2014 | 5/27/2014 | 5/28/2014 8:05:44 AM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by steve sellers rough in ok
|
ELE14-00199
| Final | 5/27/2014 | 5/27/2014 | 5/27/2014 2:18:46 PM | P | PASS |
|
|
Troy Phone #: ###-#### corrections made final ok
|
ELE14-01322
| Electrical Rough-In | 5/27/2014 | 5/27/2014 | 5/27/2014 1:50:49 PM | P | FAIL |
|
|
dan Phone #: ###-#### suppor nm cable in kitchen, nailplates under panel, romex connector in bottom of panel, replace old metal box to meet wire fill requirements at fridge.
|
ELE14-00866
| Final | 5/27/2014 | 5/27/2014 | 5/27/2014 1:10:25 PM | P | FAIL |
|
|
Tim - ###-#### Phone #: ###-#### >> Inspection requested via web by Tim Lawrence 210.52 (C)(3) kitchen peninsular needs receptacle. 314.20- garbage disposal receptacle needs flash ring and cover. range not hooked up, reverse polarity in kitchen recepts. lock off on d/washer breaker. Additional fees for additional work done throughout house.
|
GCE14-00048
| GCE-Final | 5/27/2014 | 5/27/2014 | 5/27/2014 12:38:42 PM | P | PASS |
|
|
Eric ###-#### final ok
|
ELE14-01183
| Electrical Rough-In | 5/23/2014 | 5/27/2014 | 5/27/2014 11:49:58 AM | P | PASS |
|
|
call mike to meet at main entry.... please verify isolated ground issues are OK to leave as is Phone #: ###-#### >> Inspection requested via web by Mike Basye rough in walls ok 1st floor and third floor
|
ELE12-00989
| ELE-Aging Inspection | 5/27/2014 | 5/27/2014 | 5/27/2014 10:38:09 AM | | DONE |
|
|
left message
|
ELE12-00212
| ELE-Aging Inspection | 5/27/2014 | 5/27/2014 | 5/27/2014 10:35:48 AM | | DONE |
|
|
no phone number
|
ELE14-01255
| Rough-In Permanent Service | 5/27/2014 | 5/27/2014 | 5/27/2014 9:42:31 AM | A | PASS |
|
|
Ready for rough in and service connection house is open in back for inspector thanks Phone #: ###-#### >> Inspection requested via web by Kevin Oderkirk rough in ok p/s o/h rec ok
|
ELE14-01327
| Final | 5/23/2014 | 5/27/2014 | 5/27/2014 9:03:19 AM | A | PASS |
|
|
>> Inspection requested via web by steve ragan final ok
|
ELE14-01326
| Final | 5/23/2014 | 5/27/2014 | 5/27/2014 9:02:35 AM | A | PASS |
|
|
>> Inspection requested via web by steve ragan final ok
|
ELE14-00964
| Electrical Rough-In | 5/22/2014 | 5/27/2014 | 5/27/2014 8:45:45 AM | A | PASS |
|
|
Contact: Mike Butticci Phone #: ###-#### >> Inspection requested via web by Deb Gooden 3rd floor north misc. walls indicated on plans ok to cover
|