Inspections for the day of: Tuesday, May 27, 2014.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC14-01427 Rough-in5/27/20145/27/20145/27/2014 4:45:19 PMPFAIL
Melissa Phone #: ###-#### - Failed flue pressure test, Need to seal all joints on duct work, Need to install bath room exhaust fans, need to install either a transfer grill or ducted return in bedroom.
MEC14-02018 Final5/27/20145/27/20145/27/2014 4:19:37 PMPPASS
Please be in the latest afternoon as possible with a call to Aleks ###-####. Thanks Phone #: ###-#### >> Inspection requested via web by Allie Courter
MEC14-01998 Final5/23/20145/27/20145/27/2014 4:02:46 PMPPASS
Please Call Dwight ###-#### @ Jims heating Prior To Inspection, Thank You Phone #: ###-#### >> Inspection requested via web by Manuel Acuna
MEC14-01427 Pressure Test5/27/20145/27/20145/27/2014 3:41:25 PMPPASS
Melissa Phone #: ###-#### - 20LB GAS PRESSURE PASS
MEC14-01996 Rough-in5/27/20145/27/20145/27/2014 3:18:25 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Karl Hestekin
MEC14-01428 Final5/27/20145/27/20145/27/2014 2:35:06 PMPPASS
>> Inspection requested via web by Konrad Swartz
MEC14-00893 Final5/27/20145/27/20145/27/2014 2:16:46 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Dan Otero -
MEC14-01310 Final5/27/20145/27/20145/27/2014 2:06:19 PMPFAIL
Garage Code: 2738
Adam: ###-#### Phone #: ###-#### >> Inspection requested via web by Frank Marturello - need to redue air balance, Total CFM value is to low per manual j.
MEC14-01923 Final5/23/20145/27/20145/27/2014 11:43:09 AMAPASS
Customer Name: Lester Rose, ###-#### Phone #: ###-#### >> Inspection requested via web by cheryl shroll
MEC14-01899 Final5/23/20145/27/20145/27/2014 11:01:42 AMANH
Customer Name: Pamela Cook, ###-#### Phone #: ###-#### >> Inspection requested via web by cheryl shroll
MEC14-01967 Rough-in5/23/20145/27/20145/27/2014 10:21:54 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Krista Boss - need to relocate attic access, it is blocked by duct work. Fresh air duct is not the correct size, needs to be 6". need to complete b-vent for water heater, need 1" clearance between insulation shield & b-vent, need 1" clearance to combustable from b-vent. need to pressure test pvc flue.
MEC14-01967 Pressure Test5/23/20145/27/20145/27/2014 10:18:47 AMANR
Phone #: ###-#### >> Inspection requested via web by Krista Boss
MEC14-01997 Final5/23/20145/27/20145/27/2014 9:51:42 AMAPASS
Robert Phone #: ###-####
MEC14-01962 Pressure Test5/22/20145/27/20145/27/2014 9:15:31 AMAPASS
Adam: ###-#### Phone #: ###-#### >> Inspection requested via web by Frank Marturello - 20LB GAS PRESSURE PASS, 5LB FLUE PRESSURE PASS
MEC14-01962 Rough-in5/22/20145/27/20145/27/2014 9:14:25 AMAPASS
Adam: ###-#### Phone #: ###-#### >> Inspection requested via web by Frank Marturello