MEC20-02081
| Final | 5/27/2020 | 5/28/2020 | 5/28/2020 3:48:17 PM | P | PASS |
|
|
Please call Rob on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil co locking caps ok
|
MEC20-02067
| Final | 5/27/2020 | 5/28/2020 | 5/28/2020 2:55:33 PM | P | PASS |
|
|
Please call Devin on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil co locking caps ok
|
MEC20-01454
| Final | 5/26/2020 | 5/28/2020 | 5/28/2020 1:56:39 PM | P | FAIL |
|
|
Please call Ezekial Messenger prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co locking caps gas piping ok- need to fix all rips and tears in arma flex and support in approved manner- need to install metal around b vent where enters into chimney and seal with firecaulk mortar was removed- send pics for reinspect
|
MEC20-02106
| Final | 5/28/2020 | 5/28/2020 | 5/28/2020 1:30:05 PM | P | NR |
|
|
Please call Paul prior to arrival to ensure ready for inspection. ###-####. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- still installing- please reschedule
|
MEC20-01292
| Final | 5/27/2020 | 5/28/2020 | 5/28/2020 11:00:50 AM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by Tim Petsche- need air balance report onsite or send to bscoles@cityofboise.org- temp occupancy ok- no occupancy card onsite to sign
|
MEC20-02000
| Final | 5/27/2020 | 5/28/2020 | 5/28/2020 10:28:27 AM | A | PASS |
|
|
call ###-#### Lisa- furnace a/c coil co locking caps ok
|
MEC19-05755
| Final | 5/28/2020 | 5/28/2020 | 5/28/2020 9:39:35 AM | A | NR |
|
|
Waiting for approved manual J from city, please homeowner 30 minutes in advance for access at ###-#### call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum 1- need approved man j onsite 2- need to remove enclosure around range duct to verify seal and ducting 3- need to witness duct blast test- please schedule 4- need to filter outside air in attic since filter grills installed 5- need locking caps on condenser
please reschedule
|
MEC19-04391
| Final | 5/28/2020 | 5/28/2020 | 5/28/2020 9:35:07 AM | A | NR |
|
|
Waiting for approved manual J from city, please homeowner 30 minutes in advance for access at ###-#### call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum 1- need approved man j onsite 2- need to remove enclosure around range duct to verify seal and ducting 3- need to witness duct blast test 4- need to filter outside air in attic since has filter grills installed 5- need locking caps on condenser
schedule duct blast test when ready
|
MEC20-02060
| Final | 5/27/2020 | 5/28/2020 | 5/28/2020 9:15:09 AM | A | PASS |
|
|
Please call Deborah prior to arrival at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace a/c coil co locking caps ok
|
MEC20-00888
| Final | 5/21/2020 | 5/28/2020 | 5/28/2020 8:36:05 AM | A | PASS |
|
|
SANTIAGO ###-#### - CALL FOR ACCESS Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace final ok
|
MEC18-05895
| Mec-Aging Inspection | 5/28/2020 | 5/28/2020 | 5/28/2020 8:09:34 AM | | DONE |
|
|
called contractor to schedule inspection- permit will expire next aging if no activity
|
MEC19-03515
| Mec-Aging Inspection | 5/28/2020 | 5/28/2020 | 5/28/2020 8:06:00 AM | | CANC |
|
|
permit expired
|
MEC19-03515
| DOC - Permit Expired | 5/28/2020 | 5/28/2020 | 5/28/2020 8:05:47 AM | A | PASS |
|
|
no calls- permit expired
|