ELE07-00925
| Final | 5/29/2007 | 5/29/2007 | 5/29/2007 3:39:15 PM | P | PASS |
|
|
brandon ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok to final
|
ELE07-00704
| Final | 5/29/2007 | 5/29/2007 | 5/29/2007 3:13:28 PM | P | PASS |
|
|
Craig ###-#### corrections made, ok to final
|
ELE07-00200
| Final | 5/29/2007 | 5/29/2007 | 5/29/2007 2:47:22 PM | P | PASS |
|
|
Reinspection Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called to work on circ directory, and address, ok to final
|
ELE07-00198
| Final | 5/29/2007 | 5/29/2007 | 5/29/2007 2:17:55 PM | P | FAIL |
|
|
Reinspection Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called, corrections not made,
|
ELE07-00197
| Final | 5/29/2007 | 5/29/2007 | 5/29/2007 1:58:36 PM | P | FAIL |
|
|
Reinspection Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called, left message, corrections not made
|
ELE07-01827
| Permanent Service | 5/29/2007 | 5/29/2007 | 5/29/2007 1:48:04 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 5/29/2007 at 9:16:03 AM. Contact: ###-####. called, told contr to change abrasion prot for gec, use job id sticker, need to check shack once installed, p/s o/h n ok
|
ELE07-01894
| Electrical Rough-In | 5/29/2007 | 5/29/2007 | 5/29/2007 12:55:24 PM | P | PASS |
|
|
rough in only ###-#### Internet Inspection Request from: Todd Holbrook called about recpt, nail plate, ric ok
|
ELE07-00647
| Final | 5/29/2007 | 5/29/2007 | 5/29/2007 12:24:07 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 5/29/2007 at 8:20:54 AM. Contact: ###-####. n ok to final
|
ELE07-01648
| Permanent Service | 5/29/2007 | 5/29/2007 | 5/29/2007 12:08:48 PM | P | PASS |
|
|
p/s exst pedestal rec ok
|
ELE07-01907
| Electrical Rough-In | 5/25/2007 | 5/29/2007 | 5/29/2007 11:07:19 AM | A | PASS |
|
|
chad - pls call an hour before inspection; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ric ok
|
ELE05-03150
| Final | 5/25/2007 | 5/29/2007 | 5/29/2007 10:39:58 AM | A | PASS |
|
|
Ready for the Final. Thanks Phone #: ###-#### x0000 Internet Inspection Request from: BRIAN KEITH met contr, sogned occ card, ok to final, checking on bowling alley
|
ELE07-01551
| Electrical Rough-In | 5/25/2007 | 5/29/2007 | 5/29/2007 9:09:33 AM | A | PART |
|
|
joe Note: west side rm 2nd floor ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles 2nd floor rooms west side anop ok to cover
|
ELE06-03238
| Final | 5/25/2007 | 5/29/2007 | 5/29/2007 8:28:39 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 5/25/2007 at 10:26:51 AM. Contact: ###-####. told owner to use in-use cover, ok to final
|
ELE07-01908
| Temporary Service | 5/25/2007 | 5/29/2007 | 5/29/2007 7:56:53 AM | A | FAIL |
|
|
schaffeld; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called, left corr notice, nec 250.53(G) ground rods shall be driven such that 8' is in contact with earth, and or 45 degrees or less, 590.6(B) ground fault protection shall be provided for other than 15 or 20a recpts, 312.5 abrasion protection shall be provided for all conductors entering enclosures, BCC job id sticker shall be posted
|