Inspections for the day of: Tuesday, May 29, 2012.
Number of inspections: 18
Percentage of inspections complete: 94 %
Percentage of inspections not complete: 6 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC11-00878 General Inspection5/29/20125/29/20126/6/2012 2:10:50 PM PASS
site clean,erosion and sediment controls inplace
ESC11-00765 Aging Inspection5/29/20125/29/20126/6/2012 1:41:56 PM PASS
site clean, ready for final
ELE11-00957 ELE-Aging Inspection5/29/20125/29/20125/29/2012 3:23:14 PM PASS
see final
ELE11-00957 Final5/29/20125/29/20125/29/2012 3:22:42 PMPPASS
Change from overhead service to underground, final ok
ELE11-00944 ELE-Aging Inspection5/29/20125/29/20125/29/2012 3:19:50 PM PASS
still under construction
GCE12-00071 GCE-Rough-In Permanent Service5/29/20125/29/20125/29/2012 3:02:04 PMPPASS
(Mandatory Inspection)
Dan @ ###-#### rough-in ok cover
ELE12-01179 Electrical Rough-In5/29/20125/29/20125/29/2012 2:13:15 PMPFAIL
bob Phone #: ###-#### NEC 314.20 Outside fixture boxes mounted in walls constructed of wood shall be flush with surface NEC334.30 NM cable shall be stapled within 8 in of box, 12 in. if box has loom clamps
ELE12-01192 Permanent Service5/29/20125/29/20125/29/2012 1:35:42 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Chris Berthelot p/s u/g n ok
ELE12-01220 Electrical Rough-In5/29/20125/29/20125/29/2012 1:12:07 PMPPASS
wall & ceiling Phone #: ###-#### >> Inspection requested via web by Clint Tate rough-in ok cover walls, security entry room
ELE11-02687 Final5/25/20125/29/20125/29/2012 12:47:05 PMPPASS
Robert Phone #: ###-#### final ok
GCE12-00030 GCE-Final5/25/20125/29/20125/29/2012 12:23:57 PMAPASS
(Mandatory Inspection)
###-#### final ok
ELE12-00660 Final5/25/20125/29/20125/29/2012 10:23:49 AMAPASS
Frank Phone #: ###-#### final ok
ELE11-02312 Final5/29/20125/29/20125/29/2012 9:35:15 AMAPASS
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI final ok
ELE11-02657 Rough-In Permanent Service5/22/20125/29/20125/29/2012 9:18:41 AMANR
Phone #: ###-#### >> Inspection requested via web by Brandon Winters
ELE12-00824 Final5/28/20125/29/20125/29/2012 9:03:25 AMANR
Please call prior to inspection. Phone #: ###-#### >> Inspection requested via web by Dan Wright
ELE12-00824 Electrical Rough-In5/28/20125/29/20125/29/2012 9:02:51 AMAPASS
Please call prior to inspection. Phone #: ###-#### >> Inspection requested via web by Dan Wright rough-in ok cover ceiling grid
ELE11-02384 Rough-In Permanent Service5/25/20125/29/20125/29/2012 8:27:49 AMAPASS
service inspection for MRI connection. roof top electrical. call Nick 30 min. prior Phone #: ###-#### >> Inspection requested via web by Shawna Gates r/i p/s MRI disconnect
ESC11-00764 Aging Inspection5/29/20125/29/2012