Inspections for the day of: Tuesday, May 29, 2018.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM18-01132 Final5/23/20185/29/20185/29/2018 4:50:00 PMPFAIL
Phone #: ###-#### Inspection requested via web by mark hey. Pressure test the water heater flue
PLM14-00050 DOC - Permit Finaled5/29/20185/29/20185/29/2018 4:48:14 PMPPASS
complete by picture
PLM18-02100 Groundwork5/29/20185/29/20185/29/2018 4:13:15 PMPFAIL
if questions call Ryan @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann.
Cannot use a double wye on horizontal to horizontal. Fitting not listed for that.
Check grade on trap arms.
PLM14-00050 Final5/29/20185/29/20185/29/2018 3:24:11 PMPPART
Gracey Phone #: ###-####.
Install a vacuum breaker on the handshower outlet. Outlet is below the shower valve
PLM18-02202 Water Heater Final5/28/20185/29/20185/29/2018 2:51:40 PMPPASS
Try front office to buzz you in if not call me for code. Phone #: ###-#### Inspection requested via web by LANDON ADANK
PLM18-02178 Other5/24/20185/29/20185/29/2018 2:43:29 PMPNH
Inspection requested via web by Robert Sisk
PLM18-02081 Water and/or Sewer5/28/20185/29/20185/29/2018 2:43:07 PMPFAIL
Inspection requested via web by Dereck Cumpton.
Need 1/8"/ft grade
PLM18-02201 Final5/29/20185/29/20185/29/2018 12:26:21 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
PLM18-02203 Water and/or Sewer5/28/20185/29/20185/29/2018 12:18:26 PMPPASS
Phone #: ###-#### Inspection requested via web by Danny Miller
PLM18-02203 DOC - Permit Finaled5/29/20185/29/20185/29/2018 12:18:14 PMPPASS
PLM18-02204 Water and/or Sewer5/28/20185/29/20185/29/2018 12:17:59 PMPPASS
Inspection requested via web by Danny Miller
PLM18-02204 DOC - Permit Finaled5/29/20185/29/20185/29/2018 12:17:47 PMPPASS
PLM17-02424 DOC - Permit Finaled5/29/20185/29/20185/29/2018 11:45:43 AMPPASS
PLM18-01733 DOC - Permit Finaled5/29/20185/29/20185/29/2018 11:41:53 AMPPASS
PLM17-03321 DOC - Permit Expired5/29/20185/29/20185/29/2018 11:31:52 AMPPASS
contractor failed to respond
PLM18-01203 Final5/25/20185/29/20185/29/2018 11:24:39 AMAFAIL
#19631
7373 enter Phone #: ###-#### Inspection requested via web by Ann Marie Reyes.
The water heater drain pan is too small. Must be 4" larger than the water heater diameter per the manufactures instruction.
PLM18-00775 Plumbing Rough-in5/25/20185/29/20185/29/2018 11:05:19 AMPPASS
Door code is 1669 Phone #: ###-#### Inspection requested via web by Steve Spence
PLM18-02172 Final5/29/20185/29/20185/29/2018 10:37:58 AMPPASS
Failed this morning because of no CO detectors. The CO detectors are now installed. Phone #: ###-#### Inspection requested via web by Krista Boss
PLM18-02195 Sprinkler (Final)5/25/20185/29/20185/29/2018 10:37:03 AMAPASS
call 10 mins ahead- Terry Phone #: ###-####
PLM18-01907 Sprinkler (Final)5/29/20185/29/20185/29/2018 10:26:33 AMAPASS
Backflow Phone #: ###-#### Inspection requested via web by Charles Parks
PLM18-02047 Other5/25/20185/29/20185/29/2018 10:20:03 AMAPASS
Please meet our field supervisor, Don Rapp, ###-####, on site to evaluate T;P out of basement into crawl or a water alarm. Between 10 - 11 Phone #: ###-#### Inspection requested via web by Mary LaFayette.
Contractor will pipe the t&p outside and drill relief hole at the low point
PLM18-02153 Water Heater Final5/23/20185/29/20185/29/2018 9:44:29 AMPCANC
Please call ###-#### when on way Phone #: ###-#### >> Inspection requested via web by JEREMY LINK Inspection cancelled from web by: JEREMY LINK
PLM18-01945 Final5/25/20185/29/20185/29/2018 9:28:57 AMAPASS
Homeowner should be around. If not call Mike Geno at ###-#### for access. Phone #: ###-#### Inspection requested via web by Josh Johnson
PLM18-02172 Final5/25/20185/29/20185/29/2018 9:00:48 AMAFAIL
AM. Please call the customer when on way ###-####. Phone #: ###-#### Inspection requested via web by Krista Boss.
Provide CO detectors
PLM18-02129 Water Heater Final5/22/20185/29/20185/29/2018 8:41:07 AMAPASS
Please call when on way ###-#### Phone #: ###-#### Inspection requested via web by JEREMY LINK